# A02 Present Pipe Spec

### Definition

Select the pipe standard used by the flowmeter. Default: custom.

<table data-full-width="false"><thead><tr><th width="103.521484375">Model</th><th width="167.228515625" valign="top">Pipe Spec Options</th><th width="182.3515625" valign="top"></th><th width="138.6884765625" valign="top"></th><th valign="top"></th></tr></thead><tbody><tr><td><p>FU-LT008</p><p>(DN8)</p></td><td valign="top"><p><strong>Metal</strong></p><ul><li>JIS G3459：SCH40 / SCH80 / 8A</li><li>ISO SUS</li><li>DIN 1850 SUS</li><li>Copper Type L</li></ul></td><td valign="top"><p><strong>Plastic</strong></p><ul><li>ISO 15494 PPH</li><li>ISO 10931 PVDF</li><li>ISO 8061 PVC</li><li>ISO 15493 ABS</li></ul></td><td valign="top"><p><strong>PFA</strong></p><ul><li>1/2" PFA</li><li>12 mm PFA</li><li>12 mm PFA（W1.5）</li><li>13 mm PFA</li></ul></td><td valign="top"><p><strong>Others</strong></p><ul><li>custom</li></ul></td></tr><tr><td><p>FU-LT010</p><p>(DN10)</p></td><td valign="top"><p><strong>Metal</strong></p><ul><li>ASTM SUS：SCH40 / SCH80</li><li>JIS G3459：SCH40 / SCH80 / 10A</li><li>ISO SUS</li><li>DIN 1850 SUS</li><li>Copper Type L</li></ul></td><td valign="top"><p><strong>Plastic</strong></p><ul><li>ISO 15494 PPH</li><li>ISO 10931 PVDF</li><li>ISO 8061 PVC</li><li>ISO 4427 PE</li><li>ISO 15493 ABS</li><li>JIS K6742 PVC-U</li><li>ASTM PVC：SCH40 / SCH80</li><li>CNS W PVC</li><li>CNS E PVC</li></ul></td><td valign="top"><p><strong>PFA</strong></p><ul><li>5/8 PFA</li></ul></td><td valign="top"><p><strong>Others</strong></p><ul><li>custom</li></ul></td></tr><tr><td><p>FU-LT015</p><p>(DN15)</p></td><td valign="top"><p><strong>Metal</strong></p><ul><li>ASTM SUS：SCH40 / SCH80 / SCH120</li><li>JIS G3459：SCH40 / 15A</li><li>ISO SUS</li><li>DIN 1850 SUS</li><li>Copper Type L：19 mm / 22 mm</li></ul></td><td valign="top"><p><strong>Plastic</strong></p><ul><li>ISO 15494 PPH</li><li>ISO 10931 PVDF</li><li>ISO 8061 PVC</li><li>ISO 4427 PE</li><li>ISO 15493 ABS</li><li>JIS K6742 PVC-U</li><li>ASTM PVC：SCH40 / SCH80 / SCH120</li><li>CNS W PVC</li><li>CNS E PVC</li></ul></td><td valign="top"><p><strong>PFA</strong></p><ul><li>3/4" PFA</li><li>19 mm PFA</li></ul></td><td valign="top"><p><strong>Others</strong></p><ul><li>custom</li></ul></td></tr><tr><td><p>FU-LT020</p><p>(DN20)</p></td><td valign="top"><p><strong>Metal</strong></p><ul><li>ASTM SUS：SCH40 / SCH80 / SCH120</li><li>JIS G3459：SCH40 / 20A</li><li>JIS G3447：1S</li><li>ISO SUS</li><li>DIN 1850 SUS</li><li>Copper Type L</li></ul></td><td valign="top"><p><strong>Plastic</strong></p><ul><li>ISO 15494 PPH</li><li>ISO 10931 PVDF</li><li>ISO 8061 PVC</li><li>ISO 4427 PE</li><li>ISO 15493 ABS</li><li>ASTM PVC：SCH40 / SCH80 / SCH120</li><li>JIS K6742 PVC-U</li><li>CNS W PVC</li><li>CNS E PVC</li></ul></td><td valign="top"><p><strong>PFA</strong></p><ul><li>1 PFA</li><li>25mm PFA</li></ul></td><td valign="top"><p><strong>Others</strong></p><ul><li><p>3A Standard： </p><p>3A 1.25mm, </p><p>3A 1.65mm</p></li><li>custom</li></ul></td></tr><tr><td><p>FU-LT025</p><p>(DN25)</p></td><td valign="top"><p><strong>Metal</strong></p><ul><li>ASTM SUS：SCH80</li><li>ISO SUS</li><li>DIN 1850 SUS</li><li>JIS G3459：SCH40 / 25A</li><li>JIS G3447：1.25S</li><li>Copper Type L</li></ul></td><td valign="top"><p><strong>Plastic</strong></p><ul><li>ISO 15494 PPH</li><li>ISO 10931 PVDF</li><li>ISO 8061 PVC</li><li>ISO 4427 PE</li><li>ISO 15493 ABS</li><li>ASTM PVC：SCH40 / SCH80 / SCH120</li><li>JIS K6742 PVC-U</li><li>CNS W PVC</li><li>CNS E PVC</li></ul></td><td valign="top"><strong>PFA</strong></td><td valign="top"><p><strong>Others</strong></p><ul><li>custom</li></ul></td></tr></tbody></table>

### Notes

1. <mark style="color:red;">Each time the pipeline size is changed, perform</mark> <mark style="color:red;"></mark><mark style="color:red;">**Z03 Auto Initialize**</mark> <mark style="color:red;"></mark><mark style="color:red;">and</mark> <mark style="color:red;"></mark><mark style="color:red;">**Z04 Auto Zero Offset**</mark> <mark style="color:red;"></mark><mark style="color:red;">to ensure accurate flow readings and maintain stable product quality.</mark>
2. Tube specifications vary depending on the model and firmware version. Confirm the machine’s model and version to select the correct tube specification table. To check the model and version, follow the steps below:

<table><thead><tr><th valign="top">H12 System Info</th><th valign="top">Startup Screen</th><th valign="top">Device Label</th></tr></thead><tbody><tr><td valign="top"><p>Access parameter H12 – System Info to verify the device model and main unit version.</p><ul><li><strong>P1003</strong>: Device firmware version (identical to the version shown on the startup screen)</li><li><strong>D1003</strong> and <strong>S1102</strong>: Hardware version</li><li><strong>008</strong>: Device model (DN8 pipe size)</li></ul></td><td valign="top"><p>The startup screen is displayed for approximately three seconds after the flowmeter is powered on.</p><ul><li><strong>LORRIC</strong>: Trademark</li><li><strong>FU-LT 008</strong>: Device model (DN8 pipe size)</li><li><strong>P1003</strong>: Device firmware version</li></ul></td><td valign="top"><p>A label is affixed to the flowmeter housing.</p><ul><li><strong>FU-LT 008</strong>: Device model (DN8 pipe size)</li><li><strong>SN: 08-039</strong>: Device serial number</li></ul><p>Note: The label may become unreadable over time. Record the serial number upon receipt.</p></td></tr><tr><td valign="top"><img src="https://content.gitbook.com/content/i4ECt41Kyy9211OWazj4/blobs/9DCUoCWeqM5W51cwNZMv/image" alt=""></td><td valign="top"><img src="https://content.gitbook.com/content/i4ECt41Kyy9211OWazj4/blobs/8BcGNbJLmMqb96Kl1eep/image" alt=""></td><td valign="top"><img src="https://content.gitbook.com/content/i4ECt41Kyy9211OWazj4/blobs/AwSaG8coGpWLnlEiOiPd/image" alt=""></td></tr></tbody></table>

### Operation Procedure

<details>

<summary><strong>Button Functions (Click to Expand)</strong></summary>

The main unit has **four buttons**. The **bottom line (Line 3)** of the LCD displays the current function of each button. Under normal operation, the button functions are as follows:

* <img src="https://content.gitbook.com/content/i4ECt41Kyy9211OWazj4/blobs/BZuNjMgY75LH0onY5NtL/image" alt="" data-size="line"> **Blue Button -** Leftmost button: Return, exit, or save settings.

Gray Arrow Buttons:

* <img src="https://content.gitbook.com/content/i4ECt41Kyy9211OWazj4/blobs/Br88VpmnPLAPdutxVdZb/image" alt="" data-size="line"> **Left Gray Button:** Page up, increase value, or select item
* <img src="https://content.gitbook.com/content/i4ECt41Kyy9211OWazj4/blobs/3Dzp8nuxmHsaZ7LqBscw/image" alt="" data-size="line"> **Right Gray Button:** Page down, decrease value, or select item
* <img src="https://content.gitbook.com/content/i4ECt41Kyy9211OWazj4/blobs/sq6fX6r39JE0Au2hahAR/image" alt="" data-size="line"> **Orange Button:** Rightmost button: Enter settings, edit, or confirm selection

{% hint style="danger" %}
**Do not hold buttons for extended periods to avoid damage.**
{% endhint %}

{% hint style="info" %}
Button functions may change depending on the operation context to improve usability or prevent accidental presses.
{% endhint %}

</details>

```
A02 Present Pipe Spec Setting Steps
• From the main screen (green backlight), 
  press Orange Button (Setup) to enter settings (orange backlight).
• Use Gray Arrow Buttons to select A. Measurement , press Orange Button (Enter).
• Use Gray Arrow Buttons to select A02 Present Pipe Spec, press Orange Button (Enter).
• Use Gray Arrow Buttons to choose the options. 
• Press Orange Button (Set) to confirm.
• Press Blue Button (ESC) to return to the main screen (green backlight).
```

<figure><img src="https://3404778090-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2Fi4ECt41Kyy9211OWazj4%2Fuploads%2FG6F0JOQjM45F3iegLcYZ%2FFU-LT-A02-en.png?alt=media&#x26;token=b93bd669-1bb0-40af-9454-b90a2da28577" alt="" width="375"><figcaption></figcaption></figure>

### A02 Options and RS485 Values, Read/Write Commands, and Formats

Refer to the tube specification table corresponding to the model.

#### A02 Tube Specification – Model FU-LT008, Version P1002 / P1003 Parameter Table

<table data-full-width="false"><thead><tr><th>FU-LT008</th><th>RS-485 int</th></tr></thead><tbody><tr><td>custom</td><td>0(Custom)</td></tr><tr><td>JIS G3459 sch40</td><td>1</td></tr><tr><td>JIS G3459 sch80</td><td>2</td></tr><tr><td>JIS G3459 8a</td><td>3</td></tr><tr><td>ISO 15494 PPH</td><td>4</td></tr><tr><td>ISO 10931 PVDF</td><td>5</td></tr><tr><td>ISO 8061 PVC</td><td>6</td></tr><tr><td>ISO 15493 ABS</td><td>7</td></tr><tr><td>ISO SUS</td><td>8</td></tr><tr><td>1/2 PFA</td><td>9</td></tr><tr><td>12mm PFA</td><td>10</td></tr><tr><td>12mm PFA W1.5</td><td>11</td></tr><tr><td>13mm PFA</td><td>12</td></tr><tr><td>DIN1850 SUS</td><td>13</td></tr><tr><td>Copper Type L</td><td>14</td></tr></tbody></table>

#### A02 **Tube Specification – Model FU-LT010, Version P1002 / P1003 Parameter Table**

<table data-full-width="false"><thead><tr><th>FU-LT010</th><th>RS-485 int</th></tr></thead><tbody><tr><td>custom</td><td>0(Custom)</td></tr><tr><td>CNS W</td><td>1</td></tr><tr><td>CNS E</td><td>2</td></tr><tr><td>JIS K6742</td><td>3</td></tr><tr><td>ASTM SCH40 PVC</td><td>4</td></tr><tr><td>ASTM SCH40 SUS</td><td>5</td></tr><tr><td>ASTM SCH80 PVC</td><td>6</td></tr><tr><td>ASTM SCH80 SUS</td><td>7</td></tr><tr><td>JIS G3459 sch40</td><td>8</td></tr><tr><td>JIS G3459 sch80</td><td>9</td></tr><tr><td>JIS G3459 10a</td><td>10</td></tr><tr><td>ISO 15494 PPH</td><td>11</td></tr><tr><td>ISO 10931 PVDF</td><td>12</td></tr><tr><td>ISO 8061 PVC</td><td>13</td></tr><tr><td>ISO 4427 PE</td><td>14</td></tr><tr><td>ISO 15493 ABS</td><td>15</td></tr><tr><td>ISO SUS</td><td>16</td></tr><tr><td>5/8 PFA</td><td>17</td></tr><tr><td>DIN1850 SUS</td><td>18</td></tr><tr><td>Copper Type L</td><td>19</td></tr></tbody></table>

#### **A02 Tube Specification – Model FU-LT015, Version P1002 / P1003 Parameter Table**&#x20;

<table data-full-width="false"><thead><tr><th>FU-LT015</th><th>RS-485 int</th></tr></thead><tbody><tr><td>custom</td><td>0(Custom)</td></tr><tr><td>CNS W</td><td>1</td></tr><tr><td>CNS E</td><td>2</td></tr><tr><td>JIS K6742</td><td>3</td></tr><tr><td>ASTM SCH40 PVC</td><td>4</td></tr><tr><td>ASTM SCH40 SUS</td><td>5</td></tr><tr><td>ASTM SCH80 PVC</td><td>6</td></tr><tr><td>ASTM SCH80 SUS</td><td>7</td></tr><tr><td>ASTM SCH120 PVC</td><td>8</td></tr><tr><td>ASTM SCH120 SUS</td><td>9</td></tr><tr><td>JIS G3459 sch40</td><td>10</td></tr><tr><td>JIS G3459 15a</td><td>11</td></tr><tr><td>ISO 15494 PPH</td><td>12</td></tr><tr><td>ISO 10931 PVDF</td><td>13</td></tr><tr><td>ISO 8061 PVC</td><td>14</td></tr><tr><td>ISO 4427 PE</td><td>15</td></tr><tr><td>ISO 15493 ABS</td><td>16</td></tr><tr><td>ISO SUS</td><td>17</td></tr><tr><td>3/4 PFA</td><td>18</td></tr><tr><td>19mm PFA</td><td>19</td></tr><tr><td>DIN1850 SUS</td><td>20</td></tr><tr><td>Copper Type L 19mm</td><td>21</td></tr><tr><td>Copper Type L 22mm</td><td>22</td></tr></tbody></table>

#### **A02 Tube Specification – Model FU-LT020, Version P1002 / P1003 Parameter Table**&#x20;

<table data-full-width="false"><thead><tr><th>FU-LT020</th><th>RS-485 int</th></tr></thead><tbody><tr><td>custom</td><td>0(Custom)</td></tr><tr><td>CNS W</td><td>1</td></tr><tr><td>CNS E</td><td>2</td></tr><tr><td>JIS K6742</td><td>3</td></tr><tr><td>ASTM SCH40 PVC</td><td>4</td></tr><tr><td>ASTM SCH40 SUS</td><td>5</td></tr><tr><td>ASTM SCH80 PVC</td><td>6</td></tr><tr><td>ASTM SCH80 SUS</td><td>7</td></tr><tr><td>ASTM SCH120 PVC</td><td>8</td></tr><tr><td>ASTM SCH120 SUS</td><td>9</td></tr><tr><td>JIS G3459 sch40</td><td>10</td></tr><tr><td>JIS G3459 20a</td><td>11</td></tr><tr><td>JIS G3447 1S</td><td>12</td></tr><tr><td>ISO 15494 PPH</td><td>13</td></tr><tr><td>ISO 10931 PVDF</td><td>14</td></tr><tr><td>ISO 8061 PVC</td><td>15</td></tr><tr><td>ISO 4427 PE</td><td>16</td></tr><tr><td>ISO 15493 ABS</td><td>17</td></tr><tr><td>ISO SUS</td><td>18</td></tr><tr><td>3A 1.25mm</td><td>19</td></tr><tr><td>3A 1.65mm</td><td>20</td></tr><tr><td>1 PFA</td><td>21</td></tr><tr><td>25mm PFA</td><td>22</td></tr><tr><td>DIN1850 SUS</td><td>23</td></tr><tr><td>Copper Type L</td><td>24</td></tr></tbody></table>

#### **A02 Tube Specification – Model FU-LT025, Version P1002 / P1003 Parameter Table**&#x20;

<table data-full-width="false"><thead><tr><th>FU-LT025</th><th>RS-485 int</th></tr></thead><tbody><tr><td>custom</td><td>0(Custom)</td></tr><tr><td>CNS W</td><td>1</td></tr><tr><td>CNS E</td><td>2</td></tr><tr><td>JIS K6742</td><td>3</td></tr><tr><td>ASTM SCH40 PVC</td><td>4</td></tr><tr><td>ASTM SCH80 PVC</td><td>5</td></tr><tr><td>ASTM SCH80 SUS</td><td>6</td></tr><tr><td>ASTM SCH120 PVC</td><td>7</td></tr><tr><td>JIS G3459 sch40</td><td>8</td></tr><tr><td>JIS G3459 25a</td><td>9</td></tr><tr><td>JIS G3447 1.25S</td><td>10</td></tr><tr><td>ISO 15494 PPH</td><td>11</td></tr><tr><td>ISO 10931 PVDF</td><td>12</td></tr><tr><td>ISO 8061 PVC</td><td>13</td></tr><tr><td>ISO 4427 PE</td><td>14</td></tr><tr><td>ISO 15493 ABS</td><td>15</td></tr><tr><td>ISO SUS</td><td>16</td></tr><tr><td>DIN1850 SUS</td><td>17</td></tr><tr><td>Copper Type L</td><td>18</td></tr></tbody></table>