# A Measurement Setup

<table data-header-hidden><thead><tr><th width="92">No.</th><th width="164">Name</th><th>Description</th></tr></thead><tbody><tr><td><strong>No.</strong></td><td><strong>Name</strong></td><td><strong>Description</strong></td></tr><tr><td>A02</td><td>Preset Pipe Spec</td><td>Select the pipe standard used by the flowmeter. Default: custom.</td></tr><tr><td>A03</td><td>Pipe Geo. Unit</td><td>Set the pipe unit. Default: mm.</td></tr><tr><td>A04</td><td>Pipe OD</td><td>Set the pipe outer diameter. Default values vary depending on the selected pipe unit.</td></tr><tr><td>A05</td><td>Pipe Perimeter</td><td>Set the pipe circumference. Default values vary depending on the selected pipe unit.</td></tr><tr><td>A06</td><td>Pipe thickness</td><td>Set the pipe wall thickness. Default values vary depending on the selected pipe unit.</td></tr><tr><td>A07</td><td>Pipe ID</td><td>Set the pipe inner diameter. Default values vary depending on the selected pipe unit.</td></tr><tr><td>A08</td><td>Pipe Material</td><td>Set the pipe material. Default: custom.</td></tr><tr><td>A09</td><td>Pipe Soundspeed</td><td>When A08 is customized, you can manually set the sound velocity of the pipe, and the unit is set in B04. </td></tr><tr><td>A10</td><td>Liquid Type</td><td>Set the liquid type. Default: custom.</td></tr><tr><td>A12</td><td>Liquid Soundspeed</td><td>Set the liquid Soundspeed. Default: custom.</td></tr><tr><td>A13</td><td>K.Viscosity cst</td><td>Set the fluid dynamic viscosity. Default: 1.</td></tr><tr><td>A15</td><td>Damping</td><td><p>A15 Damping: Smooths flow measurement data. Default: 3.</p><p>Higher value → smoother display, smaller fluctuations, slower response.</p><p>Lower value → faster response, more sensitive to flow disturbances, larger fluctuations.</p></td></tr><tr><td>A16</td><td>Direction</td><td>Reverse flow definition. Default: normal flow.</td></tr><tr><td>A17</td><td>Neg Flow (Negative Flow)</td><td>Enable display of reverse flow. Default: on.</td></tr><tr><td>A18</td><td>Low flow cutoff</td><td>Low-flow cutoff: displays flows below the set value as zero. Default: 0 (off).</td></tr><tr><td>A19</td><td>Fast Update</td><td>Screen refresh rate: allows updates every 0.5 s. Default: off.</td></tr><tr><td>A20</td><td>Anti-Noise</td><td>Noise elimination for unstable measurements. Default: on, can be disabled.</td></tr><tr><td>A21</td><td>Auto Initialization</td><td>Auto-detect fluid ultrasonic velocity to complete environmental parameter setup after installation and parameter configuration.</td></tr><tr><td>A22</td><td>Auto Zero Offset</td><td>Auto zero calibration: resets the flowmeter output to zero. Recommended for very low flow measurement to correct zero offset errors.</td></tr><tr><td>A23</td><td>Zero Offset</td><td>Manual zero compensation: corrects internal system time offset. Unit: ns (not a flow unit). Refer to the value on the User Debug Page and input into A23.</td></tr><tr><td>A26</td><td>Beta Mode</td><td>A26: Default off. Not fully tested; do not enable.</td></tr></tbody></table>


---

# Agent Instructions: Querying This Documentation

If you need additional information that is not directly available in this page, you can query the documentation dynamically by asking a question.

Perform an HTTP GET request on the current page URL with the `ask` query parameter:

```
GET https://docs.lorric.com/qr/fu-lt-english-v1/parameters/a-measurement-setup.md?ask=<question>
```

The question should be specific, self-contained, and written in natural language.
The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.
