A Measurement Setup
No.
Name
Description
A02
Pipe Type
Select the pipe standard used by the flowmeter. Default: custom.
A03
Pipe Geo. Unit
Set the pipe unit. Default: mm.
A04
Pipe OD
Set the pipe outer diameter. Default values vary depending on the selected pipe unit.
A05
Pipe Perimeter
Set the pipe circumference. Default values vary depending on the selected pipe unit.
A06
Pipe thickness
Set the pipe wall thickness. Default values vary depending on the selected pipe unit.
A07
Pipe ID
Set the pipe inner diameter. Default values vary depending on the selected pipe unit.
A08
Pipe Material
Set the pipe material. Default: custom.
A10
Liquid Type
Set the liquid type. Default: custom.
A12
Liquid Soundspeed
Set the liquid Soundspeed. Default: custom.
A13
K.Viscosity cst
Set the fluid dynamic viscosity. Default: 1.
A15
Damping
A15 Damping: Smooths flow measurement data. Default: 3.
Higher value → smoother display, smaller fluctuations, slower response.
Lower value → faster response, more sensitive to flow disturbances, larger fluctuations.
A16
Direction
Reverse flow definition. Default: normal flow.
A17
Neg Flow (Negative Flow)
Enable display of reverse flow. Default: on.
A18
Low flow cutoff
Low-flow cutoff: displays flows below the set value as zero. Default: 0 (off).
A19
Fast Update
Screen refresh rate: allows updates every 0.5 s. Default: off.
A20
Anti-Noise
Noise elimination for unstable measurements. Default: on, can be disabled.
A21
Auto Initialization
Auto-detect fluid ultrasonic velocity to complete environmental parameter setup after installation and parameter configuration.
A22
Auto Zero Offset
Auto zero calibration: resets the flowmeter output to zero. Recommended for very low flow measurement to correct zero offset errors.
A23
Zero Offset
Manual zero compensation: corrects internal system time offset. Unit: ns (not a flow unit). Refer to the value on the User Debug Page and input into A23.
A26
Beta Mode
A26: Default off. Not fully tested; do not enable.