Product Appearance, Specifications, and Model

Appearance

Exploded View

Models & Dimensions

Model
Nominal Pipe Size
A
B
C
D
E
F

FU-LT008

DN08

105

64.1

49.2

40.44

36

14

FU-LT010

DN10

105

67.73

57.73

40.44

40.5

19

FU-LT015

DN15

105

71.13

61.13

50.9

45

23

FU-LT020

DN20

105

77.63

67.63

50.9

51.5

29

FU-LT025

DN25

105

84.96

74.96

61.12

58

35

Mechanical Specifications

Installation Method

Clamp-On

Maximum Pipe Wall Operating Temperature

Recommended ≤ 60 °C

Recommended ≤ 60 °C

-10~60°C (14~140°F)

(As fluid temperature increases, the allowable ambient temperature of the main unit must be reduced accordingly.)

Power Supply Requirement

DC 24V 200mA

Response Time

0.5 s (2 Hz) 1 s (1 Hz)

Ingress Protection

IP66**

2. Measurement Specifications

Applicable Fluids

Liquids with no or minimal solids and air bubbles

Linearity

± 0.5 % FS (>0.3m/s)

Repeatability

± 0.4 %

Accuracy

10% 至 100% of F.S. 時 ±3.0% OR

0% 至 10% of F.S. 時 ± 0.3% FS*

Measurement Principle

Ultrasonic Time of Flight(Time of Flight, ToF)

Instantaneous Data

Flow rate, flow velocity

Totalized Data

Total flow (selectable: positive, negative, or net flow)

Ingress Protection

IP66**

* Accuracy Notice Accuracy is calibrated under controlled conditions using clean water at ambient temperature with CNS UPVC pipes. Actual performance may vary due to fluid properties, pipe conditions, installation, and environmental factors.

** IP66 Rating IP66 indicates complete protection against dust and resistance to high-pressure water jets.

3. Electrical Specifications

Power Supply

DC 24V, 200 mA

(Excluding 4–20 mA and RS485 current)

Reverse Polarity Protection

Yes

4. NPN Output

Power Supply

DC 24V 200mA

Reverse Polarity Protection

Yes

Wiring

NPN supported (PNP not supported)

5. Analog Current Output (4–20 mA)

Wiring

3-wire configuration

Power Supply

Shared with the main unit; no separate power required

Output Range

2.4 ~ 21.6 mA

Response Time

1 second

(matches display update rate)

Loop Resistance

600 ohm @ 24V

6. Digital Communication: Modbus RTU (RS-485)

Baud Rate

9600, 19200, 38400, 57600

Wiring

2-wire

Maximum Nodes per Network

256

User Interface

Languages

English, Traditional Chinese, Simplified Chinese

Units

Flow: L, ft³, Imp gal, US gal, m³ Time: Minute, Second, Hour, Day Velocity: m/s, ft/s

Display

Single-screen 3-color backlit LCD, 3 lines × 16 characters (English) Line 1: Current parameter and unit Line 2: Measurement data Line 3: Key definitions (see Human-Machine Interface section)

Digits

10 digits plus sign and decimal point

Operation Keys

4-touch keys

Wired Communication

Analog Output: Powered 4–20 mA Modbus RTU: RS-485, 2-wire NPN Output (Includes 2 m signal cable, 6-core, non-isolated)

Shipping Contents

Unless otherwise specified in the order, standard shipment includes:

  • FU-LT Main Unit × 1 (with upper and lower clamps)

  • Protective Cover for Main Unit × 1

  • 2 m 6-pin Connection Cable × 1 (non-M12 connector)

  • Quick Installation Guide × 1

Last updated