Firmware Update Date and Version Feature Description

Firmware Version: P1203 Release Date: August 2024

Improvements:

  • Improvement I:

    • Added the Hybrid1 main screen.

    • Enhanced Modbus RTU functionality for large numbers (dosing/totalizer) and support for int64 data format:

      • Command 04: Enables reading of int64 large numbers.

      • Command 03: Enables reading of int64-related configuration parameters.

      • Command 31: Introduced a new 64-bit parameter write command. Modbus RTU now supports data reading for dosing.

  • Improvement II:

    • Corrected default pipeline size string and improved cumulative precision when cumulative values are extremely large.

    • Fixed an issue where an incorrect password entry displayed abnormally on the main screen when the password feature was enabled.

    • Resolved a data error when the time unit for instantaneous flow rate was set to "day."


Firmware Version: 1.202

Improvement:

  • Added Modbus RTU commands 03, 06, and 30 to enable remote parameter configuration.