Parameter Settings
Setup Procedure
1
Language Settings
H04 Language Setting Steps
- From the main screen (green backlight),
press Orange Button (Setup) to enter settings (orange backlight).
- Use Gray Arrow Buttons to select H.System, press Orange Button (Enter).
- Select H04 Language, press Orange Button (Enter).
- Choose language, press Orange Button (Set) to confirm.
- Press Blue Button (ESC) to return to main screen.
2
Pipe Setting
Easy Setup: Z02 Auto Pipe Spec
Z02 Auto Pipe Spec Setting Steps
• From the main screen (green backlight),
press Orange Button (Setup) to enter settings (orange backlight).
• Use Gray Arrow Buttons to select Z. Easy Setup, press Orange Button (Enter).
• Use Gray Arrow Buttons to select Z02 Auto Pipe Spec, press Orange Button (Enter).
• Press Right Gray Button to start Auto Pipe Spec.
• Press Blue Button (ESC) to return to the main screen (green backlight).
3
Fluid Sound Velocity Setting
Z03 Auto Initialize Setting Steps
- From the main screen (green backlight),
press Orange Button (Setup) to enter settings (orange backlight).
- Use Gray Arrow Buttons to select Z.Easy Setup, press Orange Button (Enter).
- Use Gray Arrow Buttons to select Z03 Auto Initialize,
press Orange Button (Enter).
- Press the right gray Start button to begin automatic initialization.
- After completion, press Blue Button (ESC) to return to the main screen
(green backlight).
Troubleshooting
1. Rapid Fluctuating Readings
2. No Zero at Zero Flow
FU-LT
008
010
015
020
025
3. Incorrect Positive/Negative Sign Display
4. Unit Adjustment
Last updated