Product Appearance, Specifications, and Model

Exterior

Exploded views

Models & Dimensions

Spec
A
B
C
D
E
F
G
H

FU-ES015

169.85

115

64

79

3

2.5

120.53

54

FU-ES020

169.85

115

64

79

3

2.5

124.02

54

FU-ES025

169.85

115

64

79

3

2.5

133.52

54

FU-ES032

169.85

115

64

79

3

2.5

143.02

54

Spec
A
B
C
D
E
F
G
H

FU-ES040

184.90

64

125.22

4

2.5

164.12

53.50

69.50

FU-ES050

184.90

64

125.30

4

2.5

178.12

53.50

69.50

FU-ES065

184.90

64

126.87

4

2.5

193.12

53.50

69.50

FU-ES075

184.90

64

128.55

4

2.5

207.12

53.50

69.50

Product Specifications

1. Mechanical Specifications

Installation method

Clamp-On

Maximum working temperature of pipe wall

100°C (non-UL)

Device working environment temperature

-10~60°C (14~140°F) (The higher the temperature of the fluid in the pipe, the lower the upper limit of the ambient temperature.)

Applicable pipe size

DN15-75 (1/2" to 3")

Power supply

DC 12V to 36V 200mA

Response time

≤0.5 to 1 s

2. Measurement Specifications

Applicable fluid

Clear, oil or chemicals with less impurities (<1%)

Linearity

± 0.5 % FS (>0.3m/s)

Reproducibility

± 0.4 %

OR tolerance

±3.0% RD (10%-100% F.S.)

±0.3% F.S. (0%-10% F.S.)*

Measuring principle

Time of Flight, ToF

Transient data

Instantaneous flow volume and flow velocity

Transient data

Cumulative flow (optional positive, negative or net flow)

Water proof

IP66 ** (non-UL)

*Measurement accuracy is calibrated under controlled laboratory conditions using clean water at room temperature with CNS UPVC piping. Actual results may vary depending on fluid properties, piping conditions, installation, and environmental factors.

** IP66 Ingress Protection Rating indicates protection against dust and water. The first digit 6 means complete dust protection, and the second digit 6 means protection against powerful water jets.

3. Electrical Specifications

  • Power supply

    Whole device power supply

    Working specification

    12V ~ 36V 90mA (4-20mA and RS485 current are not included.)

    Reverse voltage protection

    Yes

  • OCT output

    Power supply spec

    5V~30V 200mA

    Reverse voltage protection

    Yes

    NPN connection

    Yes

    PNP connection

    Yes

    Maximum output frequency

    700Hz

    Overcurrent protection

    200mA

  • Analog output (4-20mA, 0-20mA)

    Wiring

    3 wiring

    Power supply

    Device shares power with the main unit, no external power supply required.

    Output range

    0–20 mA or 4–20 mA (selectable)

    Maximum output range (incl. error signal)

    0~21.6 mA (0–20 mA mode) / 2.4~21.6 mA (4–20 mA mode)

    Resolution

    16-bit (0–24 mA physical range)

    Response time

    ≤0.5 to 1s (matches display update rate)

    Loop Resistance

    1100 ohm @ 36V

    600 ohm @ 24V

    250 ohm @ 12V

  • Digital communication Modbus RTU RS485

    Baud

    9600, 19200, 38400, 57600

    Wiring

    2 wiring

    Nodes on the bus

    256

4. User Interface

Language

English, Traditional Chinese, Simplified Chinese (Others customizable)

Unit

Metric: Liter, cubic meters, meters Imperial: foot, Cubic foot, Uk gallon, US gallon Time: second, minute, hour, day

Display

Double screen display :

Large 5-Digit LED, 16x3 3-Color Backlight LCD display

Display digits

LED 5 Digits (4 digits when negative value)

LCD 10 Digits (Not including sign and decimal point)

Operation buttons

4 Key touch buttons

Wired communication

Self-powered Analog output 4-20mA (Device after HW1.3) Modbus RTU RS485 Two-line OCT switch signal (ship with 2 meter cable)

Shipping Contents

Besides other agreed contents, our standard package contains:

  • FU-ES Device * 1

  • 2m 8 pin cable * 1

  • Quick starting manual * 1

Size, material, model

Screws for top side housing

Stainless steel 304

Screen cover

PMMA

Whole housing without screen cover

PC+GF

Buttons

PET

2 meters long 8 pin cable with insulation cover

Nylon

Middle lid

PPS+GF

Lower lid

PPS+GF, Silicon

Buckle

PPS+GF, PA66+GF, Silicon, Stainless steel 304

Last updated