Z02 Automatic Pipe Size Detection Guide

The Z02 automatic pipe size detection feature is designed to enhance user efficiency and accuracy. This section introduces its main functions and usage steps:

Main Functions and Steps

  1. System Startup: On the main screen, open the system menu and navigate to the "(Z Quick Menu)" interface.

  2. Settings Page: In the "(Z Quick Menu)" options interface, locate and select the "(Z02 Automatic Pipe Size Detection)" menu, then press enter.

  3. Initiate Detection: Click the “Start Detection” button. The system will automatically begin the pipe size detection process.

  4. Viewing Results: Once detection is complete, the screen will display detailed results. You can then return to the main screen.

Example Explanation

  • Example Installation: For a pipe size CNS W15 PVCU, the system will display normal detection results if installed correctly.

    • (Left Image): If a matching pipe size is found, the screen will display the pipe size name.

    • (Right Image): If no matching pipe size is found, the system will default to a CNS W size specification.

Common Reasons for Unsuccessful Z02 Detection

  • The pipe size is not in the built-in options. Refer to the A02 list for different model pipe sizes. See the pipe size guide for further details.

  • Improper installation: Excessive or insufficient torque can cause inaccurate detection results.

  • Pipe deformation due to material, pressure, wall thickness, or temperature may lead to inconsistent detection results.

Important Notes

  • Ensure the pipe is properly installed to prevent detection errors.

  • Regularly calibrate the system to maintain detection accuracy.

Last updated