FU-ES EchoSense Instruction Manual
  • ⚠Safety Instructions
  • This instruction manual version is v1.0
    • Manual Update Log
  • Measurement principle and usage scenario
    • Firmware Update Date and Version Feature Description
  • Warranty
  • Exterior, Specs, Model
  • Installation and Setup
    • Mechanism Installation
    • Mechanical and Electrical iInstallation
    • Parameter setup
      • Z02 Automatic Pipe Size Detection Guide
  • Human Machine Interface
    • Introduction of human machine interface
    • Hybrid Page Setup and Usage Interface Guide
    • Monitoring Screen
    • Simulation Mode
    • Data interpretation on monitoring screens
    • Password input page
    • Setup screen
  • Communication
    • OCT output
    • Analog current output (0-20mA, 4-20mA)
    • RS485 and Modbus RTU Setting
    • Modbus RTU Protocol
      • Read-only memory read instruction(04) and memory lists
      • Read-Write Memory List
      • Read/Write Memory Read Command (03)
      • Read-write memory single Register write instruction(06)
      • Read/Write Memory Dual-Register Write Command (30)
      • Read/Write Memory Four-Register Write Command (31)
      • Single Bit Data Read/Write Commands (01/05) (Commonly Used in HMIs)
  • Parameters Table
    • Z Category Options and Descriptions
    • A Category Options and Descriptions
      • A02 Preset Pipe Specification Table for Different Models
      • A03 ~ A07 Data Range Explanation Based on Model Specifications
    • B Category Options and Descriptions
    • K Category Options and Descriptions
    • C Category Options and Descriptions
    • D Category Options and Descriptions
    • E Category Options and Descriptions
    • F Category Options and Descriptions
    • H Category Options and Descriptions
    • Pagasfsae 1
    • Page 1
  • Alarm and description of system conditions
  • Troubleshootings and Abnormalities
    • Iout 4-20/0-20mA debug process
    • OCT Alarm Debug Process
    • OCT Pulse Debug Process
    • RS485 Debug Process
  • Certification
  • FU-ES Product Page
  • LORRIC English Website
  • LORRIC Integration and Application Center
Powered by GitBook
On this page
Export as PDF
  1. Parameters Table
  2. A Category Options and Descriptions

A02 Preset Pipe Specification Table for Different Models

The RS-485 integer correspondence table is explained as follows.

RS-485 int
015
020
025
032
040
050
065
075

0(Default)

custom

custom

custom

custom

custom

custom

custom

custom

1

CNS W15 PVCU

CNS W20 PVCU

CNS W25 PVCU

CNS W32 PVCU

CNS W40 PVCU

CNS W50 PVCU

CNS W65 PVCU

CNS W75 PVCU

2

CNS E15 PVCU

CNS E20 PVCU

CNS E25 PVCU

CNS E32 PVCU

CNS E40 PVCU

CNS E50 PVCU

CNS E65 PVCU

CNS E75 PVCU

3

JIS K6742NO.15

JIS K6742NO.20

JIS K6742NO.25

JIS K6742NO.32

JIS K6742NO.40

JIS K6742NO.50

JIS K6742NO.65

JIS K6742NO.75

4

ASTM¾"Sch40PVCU

ASTM1"Sch40PVCU

ASTMSch40PVCU

ASTMSch40PVCU

ASTMSch40PVCU

ASTMSch40PVCU

ASTMSch40PVCU

ASTMSch40PVCU

5

ASTM½"Sch40SS304

ASTM¾"Sch40SS304

ASTM1"Sch40SS304

ASTMSch40SS304

ASTMSch40SS304

ASTMSch40SS304

ASTMSch40SS304

ASTMSch40SS304

6

ASTM½"Sch80PVCU

ASTM¾"Sch80PVCU

ASTM1"Sch80PVCU

ASTMSch80PVCU

ASTMSch80PVCU

ASTMSch80PVCU

ASTMSch80PVCU

ASTMSch80PVCU

7

JIS G3459NO.15

JIS G3459NO.20

JIS G3459NO.25

JIS G3459NO.32

JIS G3459NO.40

JIS G3459NO.50

JIS G3459NO.65

JIS G3459NO.75

8

ISO 15 PP

ISO 20 PP

ISO 25 PP

ISO 32 PP

ISO 40 PP

ISO 50 PP

ISO 65 PP

ISO 75 PP

9

ISO 15 PVDF

ISO 20 PVDF

ISO 25 PVDF

ISO 32 PVDF

ISO 40 PVDF

ISO 50 PVDF

ISO 65 PVDF

ISO 75 PVDF

PreviousA Category Options and DescriptionsNextA03 ~ A07 Data Range Explanation Based on Model Specifications

Last updated 5 months ago