Monitoring screen

The monitoring screen is composed of 2 sections. The first 7 pages are real-time data monitoring. The last 15 pages are the current date, time and historical cumulative volume for the past 14 days. All the pages can be viewed cyclically by pressing the middle 2 direction buttons. Each definition on these 22 pages could be found below.

Monitoring screen detail

Page number

Page Name

LED

LCD backlight

Content of first low

Content of second low

Content of third low

Monitoring Page No.1

FLOW RATE

Data (Up to five digits)

Green means normal condition.

Red means abnormal.

Page name and unit

10-digit flow volume data

Function of each button+ simulation mode prompt.

Monitoring Page No.2

FLOW SPEED

Data (Up to five digits)

Green means normal condition.

Red means abnormal.

Page name and unit

10-digit flow speed data

Function of each button+ simulation mode prompt.

Monitoring Page No.3

TOTAL

Data (Up to five digits)

Green means normal condition.

Red means abnormal.

Page name and unit

Cumulative method+ 10-digit cumulative data

Function of each button+ simulation mode prompt.

Monitoring Page No.4

Status Page

Flow volume data

Green means normal condition.

Red means abnormal.

Alarm A

Alarm B

System Status

Monitoring Page No.5

FLOWRATE-large font

Data (Up to five digits)

Green means normal condition.

Red means abnormal.

7-digit large font flowrate data

Page name and unit

Monitoring Page No.6

FLOW SPEED-large font

Data (Up to five digits)

Green means normal condition.

Red means abnormal.

7-digit large font flow speed data

Page name and unit

Monitoring Page No.7

TOTAL-large font

Data (Up to five digits)

Green means normal condition.

Red means abnormal.

7-digit large font cumulative data

Page name, cumulative method and unit

Time

Date & Time

No

Orange

Current Time

Date + time

Function of each button

History Cumulative Volume Page No.1~14

Last 14 Days

No

Orange

Data + unit

Cumulative method+ 10-digit cumulative data

Function of each button

Monitoring Page No.1 ~ No.3

Monitoring Page No.4

Monitoring screen No. 4 is mainly for checking the status of the device, if upper and lower limit alarm functions work as expected, or for troubleshooting there will be a red light. Please see “Description of status and Alarm” for a detailed definition.

Description of Alarm A

Description of Alarm B

Description of Alarm C

Description of system status

Monitoring Page No.5 ~ No.7

Time

History Cumulative Volume Page No.1~14

Last updated