FP-AS510 Paddle Wheel Flowmeter Instruction Manual
LORRIC.com
  • ⚠Safety instructions
  • This instruction manual version is v2.0
  • Measure principle and usage scenario
  • Warranty
  • Exterior, Spec, Model
    • Device
    • Paddle set
    • T-connector
  • Install and set-up
    • Mechanism installation
    • Mechanical and electrical installation
    • Parameter setup
  • Human machine interface
    • Introduction of human machine interface
    • Monitoring screen
    • Simulation Mode
    • Data interpretation on monitoring screens
    • Password input page
    • Setup screen
  • Communication
    • OCT output
    • Analog current output (0-20mA, 4-20mA)
    • RS485 and Modbus RTU Setting
    • Modbus RTU Protocol
      • Read-only memory read instruction(04) and memory lists
      • Read-write memory list
      • Read-write memory read instruction(03)
      • Read-write memory single Register write instruction(06)
      • Read-write memory double Register write instruction(30)
  • Parameters Table
  • Alarm and description of system conditions
  • Trouble and abnormality shooting
    • Iout 4-20/0-20mA debug process
    • RS485 Debug Process
  • Certification
  • FP-AS510 Product Page
  • LORRIC English Website
  • LORRIC Integration and Application Center
Powered by GitBook
On this page
  • Exterior
  • Package contains
  • Size, material, model
  • UPVC pipe - union diameter size(mm)
  • UPVC pipe - spigot pipe diameter size(mm)
  • Device size(mm)
  • Pulse signal and flow conversion
Export as PDF
  1. Exterior, Spec, Model

T-connector

PreviousPaddle setNextInstall and set-up

Last updated 2 years ago

Exterior

Package contains

Besides other agreements, our standard package contains:

  • T-connector * 1

Union standard package contains

  • Union nuts * 2

  • Union adapter * 2

  • Union O-ring * 2

T-connector is generally shipped with a paddle set.

Size, material, model

Parts

Material

T-connector

UPVC, PPH or PVDF (for order made)

Nuts

UPVC, PPH or PVDF (for order made)

Union adapter

UPVC, PPH or PVDF (for order made)

Paddle set screws

Stainless steel 304

O-ring

EPDM、VITON、FEPM (for order made)

UPVC pipe - union diameter size(mm)

A

B

C

D

E

F

G

H

½"

164

100

27.6

36

62.3

46.2

115.7

82.2

¾"

168

100

32.6

41.9

60

50.5

115.7

85.7

1"

168

100

40.6

50

60

60

115.7

85.7

1¼"

210

114

50.2

59.6

65

75.6

127

89.2

1½"

218

120

56

65.7

70

83

134

92.5

2"

269.5

133.3

72

81

81

99.7

148.8

99

UPVC pipe - spigot pipe diameter size(mm)

A

B

C

D

E

F

2½"

160

70

76

92

106.5

152.5

Device size(mm)

I

J

63

63

Pulse signal and flow conversion

UPVC T-connector

Pipe diameter

Model

Metric ratio (pulses per litre)

US Gallon (pulses per US gal)

UK Gallon (pulses per UK gal)

3/4"

FP-P020

67.23

254.48

305.62

1"

FP-P025

53.33

201.89

242.46

1-1/4"

FP-P032

24.44

92.51

111.11

1-1/2"

FP-P040

17.02

64.43

77.38

2"

FP-P050

9.86

37.31

44.81

2-1/2"

FP-P065

5.42

20.52

24.64

If you can not see the pipe model you are currently using in the list or have other compatibility requirements, please ask our sales representative.