FP-AS510 Paddle Wheel Flowmeter Instruction Manual
LORRIC.com
  • ⚠Safety instructions
  • This instruction manual version is v2.0
  • Measure principle and usage scenario
  • Warranty
  • Exterior, Spec, Model
    • Device
    • Paddle set
    • T-connector
  • Install and set-up
    • Mechanism installation
    • Mechanical and electrical installation
    • Parameter setup
  • Human machine interface
    • Introduction of human machine interface
    • Monitoring screen
    • Simulation Mode
    • Data interpretation on monitoring screens
    • Password input page
    • Setup screen
  • Communication
    • OCT output
    • Analog current output (0-20mA, 4-20mA)
    • RS485 and Modbus RTU Setting
    • Modbus RTU Protocol
      • Read-only memory read instruction(04) and memory lists
      • Read-write memory list
      • Read-write memory read instruction(03)
      • Read-write memory single Register write instruction(06)
      • Read-write memory double Register write instruction(30)
  • Parameters Table
  • Alarm and description of system conditions
  • Trouble and abnormality shooting
    • Iout 4-20/0-20mA debug process
    • RS485 Debug Process
  • Certification
  • FP-AS510 Product Page
  • LORRIC English Website
  • LORRIC Integration and Application Center
Powered by GitBook
On this page
Export as PDF

⚠Safety instructions

The measurement method of LORRIC’s paddle wheel flowmeter is magnetism and the paddle’s rotation. Bubble, solid foreign matters, magnetic substance should be avoided. Meanwhile, there should not be any interference by strong magnetic field around the flowmeter.

The unused wires should be covered or protected to avoid electric leakage, short circuit, damage, and electric shock to humans.

If disassembling the device, please make sure there is no any foreign object on sealing of lower housing, then evenly tighten 4 screws on upper housing. If screws are not evenly tightened, it may cause damage to the housing. If not completely locked, the device may not be water and dust proof.

To avoid damaging electronic parts, please make sure the device is powered off.

The flow volume measurement of LORRIC’s paddle wheel flowmeter is based on the rotating mechanism of the paddle wheel. Paddle or shaft could be lost under long-term abrasion or impact by external forces. Users should pay careful attention to any equipment that may be damaged by missing paddle and shaft.

Pressing the button for an extended period will cause damage to the button. Please avoid excessive pressing.

After the warranty, the electronic components of the product will age due to time and operating environment. Under long-term use, please replace the new product according to the condition of the product.

Do not operate the product under an Orange or Red LCD Backlight for a long time. Product damage and related losses may occur.