Read-write memory list

How to use read-write memory list

Read-write memory type

Function

Register location

Read-write memory address is not shared with read-only memory.

Register

length

The length of variable memory. The unit is Register(2Byte).

Memory definition

For memory data description.

Data type

The format of sending and receiving data type.

Read-write function

R stands for readable, W stands for writable. Some memories are write-only.

Read-write memory list

Register location

Register length

Memory definition

Data type

Read-write function

Remarks

A group parameters

0000

1

pipe type

unsigned int 16

R/W

Multiple choice parameter type

0001

2

scale factor

float 32

R/W

0003

1

anti noise

unsigned int 16

R/W

Multiple choice parameter type

0004

1

damping

unsigned int 16

R/W

0005

1

direction

unsigned int 16

R/W

Multiple choice parameter type

0006

1

neg flow

unsigned int 16

R/W

Multiple choice parameter type

0007

1

ext mode

unsigned int 16

R/W

Multiple choice parameter type

0008

1

Fast Update

unsigned int 16

R/W

Multiple choice parameter type

B group parameters

0100

1

vol unit

unsigned int 16

R/W

Multiple choice parameter type

0101

1

time unit

unsigned int 16

R/W

Multiple choice parameter type

0102

1

total unit

unsigned int 16

R/W

Multiple choice parameter type

0103

1

speed unit

unsigned int 16

R/W

Multiple choice parameter type

0104

1

Decimal Places

unsigned int 16

R/W

Multiple choice parameter type

C group parameters

0200

1

total method

unsigned int 16

R/W

Multiple choice parameter type

0201

1

clear total

unsigned int 16

W

0202

1

history function

unsigned int 16

R/W

Multiple choice parameter type

0203

1

clear history

unsigned int 16

W

D group parameters

0300

1

paddle alarm

unsigned int 16

R/W

Multiple choice parameter type

0301

1

magnetic alarm

unsigned int 16

R/W

Multiple choice parameter type

0302

1

battery alarm

unsigned int 16

R/W

Multiple choice parameter type

0303

1

flow limit alarm

unsigned int 16

R/W

Multiple choice parameter type

0304

2

upper limit

float 32

R/W

0306

2

lower limit

float 32

R/W

0308

1

hyster value

unsigned int 16

R/W

0309

1

total alram

unsigned int 16

R/W

Multiple choice parameter type

030A

1

total trigger

unsigned int 16

R/W

Multiple choice parameter type

030B

2

total target

float 32

R/W

030D

1

iout alarm

unsigned int 16

R/W

Multiple choice parameter type

030E

1

velocity alarm

unsigned int 16

R/W

Multiple choice parameter type

030F

1

pulse overlap

unsigned int 16

R/W

Multiple choice parameter type

E group parameters

0400

1

nc no

unsigned int 16

R/W

Multiple choice parameter type

0401

1

oct info

unsigned int 16

R/W

Multiple choice parameter type

0402

1

pulse width

unsigned int 16

R/W

Multiple choice parameter type

0403

1

modbus ID

unsigned int 16

R/W

0404

1

modbus baud

unsigned int 16

R/W

Multiple choice parameter type

0405

1

iout definition

unsigned int 16

R/W

Multiple choice parameter type

0406

2

0mA/ 4mA value

float 32

R/W

0408

2

20mA value

float 32

R/W

040A

1

iout error

unsigned int 16

R/W

Multiple choice parameter type

040B

2

4mA adj

float 32

R/W

040D

2

20mA adj

float 32

R/W

040F

1

Iout Range

unsigned int 16

R/W

Multiple choice parameter type

0410

1

PulseV2Unit

unsigned int 16

R/W

Multiple choice parameter type

F group parameters

0500

2

sim rate

float 32

R/W

0502

1

sim on - reserved

const

R

0503

1

sim pulse - reserved

const

R

G group parameters

0600

1

set year*1

unsigned int 16

R/W

0601

1

set month*1

unsigned int 16

R/W

0602

1

set day*1

unsigned int 16

R/W

0603

1

set time*2

unsigned int 16

R/W

0604

1

date format

unsigned int 16

R/W

Multiple choice parameter type

H group parameters

0700

1

led brightness

unsigned int 16

R/W

Multiple choice parameter type

0701

1

lcd brightness

unsigned int 16

R/W

Multiple choice parameter type

0702

1

green light

unsigned int 16

R/W

Multiple choice parameter type

0703

1

lang

unsigned int 16

R/W

​Multiple choice parameter type

0704

1

paddle init

unsigned int 16

W

0705

1

reset

unsigned int 16

W

0706

1

Lock Device

unsigned int 16

R/W

​Multiple choice parameter type

0707

1

Password

unsigned int 16

R/W

Only 4 digits

Each definition of multiple choice memory type

Memory address

Memory definition

unsigned int 16 value

Corresponding option

Remarks

0000

pipe type

0

1 inch

1

3/4 inch

2

2 inch

3

Scale Mode

4

2-1/2 inch

5

1-1/4 inch

6

1-1/2 inch

7

1 inch V2

Memory address

Memory definition

unsigned int 16 value

Corresponding option

Remarks

0003

anti noise

0

off

1

on

Memory address

Memory definition

unsigned int 16 value

Corresponding option

Remarks

0005

direction

0

normal

1

inverse

Memory address

Memory definition

unsigned int 16 value

Corresponding option

Remarks

0006

neg flow

0

off

1

on

Memory address

Memory definition

unsigned int 16 value

Corresponding option

Remarks

0007

ext mode

0

off

1

on

Memory address

Memory definition

unsigned int 16 value

Corresponding option

Remarks

0008

Fast Update

0

off

1

on

Memory address

Memory definition

unsigned int 16 value

Corresponding option

Remarks

0100

vol unit

0

L

1

m3

2

us gallon

3

imperial gallon

4

ft3

Memory address

Memory definition

unsigned int 16 value

Corresponding option

Remarks

0101

time unit

0

second

1

minute

2

hour

3

day

Memory address

Memory definition

unsigned int 16 value

Corresponding option

Remarks

0102

total unit

0

L

1

m3

2

us gal

3

imp gal

4

ft3

Memory address

Memory definition

unsigned int 16 value

Corresponding option

Remarks

0103

speed unit

0

m/s

1

ft/s

Memory address

Memory definition

unsigned int 16 value

Corresponding option

Remarks

0104

Decimal Places

0

0

1

1

2

2

3

3

4

4

Memory address

Memory definition

unsigned int 16 value

Corresponding option

Remarks

0200

total method

0

pos

1

neg

2

net

Memory address

Memory definition

unsigned int 16 value

Corresponding option

Remarks

0202

history function

0

off

1

on

Memory address

Memory definition

unsigned int 16 value

Corresponding option

Remarks

0300

paddle alarm

0

off

1

on

Memory address

Memory definition

unsigned int 16 value

Corresponding option

Remarks

0301

magnetic alarm

0

off

1

on

Memory address

Memory definition

unsigned int 16 value

Corresponding option

Remarks

0302

battery alarm

0

off

1

on

Memory address

Memory definition

unsigned int 16 value

Corresponding option

Remarks

0303

flow limit alarm

0

off

1

on

Memory address

Memory definition

unsigned int 16 value

Corresponding option

Remarks

0309

total alarm

0

off

1

on

Memory address

Memory definition

unsigned int 16 value

Corresponding option

Remarks

030A

total trigger

0

higher than target

1

lower than target

Memory address

Memory definition

unsigned int 16 value

Corresponding option

Remarks

030D

iout alarm

0

off

1

on

Memory address

Memory definition

unsigned int 16 value

Corresponding option

Remarks

030E

velocity alarm

0

off

1

on

Memory address

Memory definition

unsigned int 16 value

Corresponding option

Remarks

030F

pulse overlap

0

off

1

on

Memory address

Memory definition

unsigned int 16 value

Corresponding option

Remarks

0400

nc no

0

nc

1

no

Memory address

Memory definition

unsigned int 16 value

Corresponding option

Remarks

0401

oct info

0

alarm a

1

alarm a b

2

alarm a b c

3

over flow volume

4

over total

5

paddle pulse

6

PulseV2

7

off

Memory address

Memory definition

unsigned int 16 value

Corresponding option

Remarks

0402

pulse width

0

0.5ms

1

1ms

2

10ms

Memory address

Memory definition

unsigned int 16 value

Corresponding option

Remarks

0404

modbus baud

0

9600

1

19200

2

38400

3

57600

4

off

Memory address

Memory definition

unsigned int 16 value

Corresponding option

Remarks

0405

iout definition

0

flow volume

1

velocity

2

total

3

off

Memory address

Memory definition

unsigned int 16 value

Corresponding option

Remarks

040A

iout error

0

2.4 mA & 21.6 mA

1

2.4 mA

2

21.6 mA

3

4&20mA or 0&20mA

Memory address

Memory definition

unsigned int 16 value

Corresponding option

Remarks

040F

Iout Range

0

4-20mA

1

0-20mA

Memory address

Memory definition

unsigned int 16 value

Corresponding option

Remarks

0410

PulseV2Unit

0

0.001

1

0.002

2

0.003

3

0.005

4

0.007

5

0.01

6

0.02

7

0.03

8

0.05

9

0.07

10

0.1

11

0.2

12

0.3

13

0.5

14

0.7

15

1.0

Memory address

Memory definition

unsigned int 16 value

Corresponding option

Remarks

0604

date format

0

yyyy-mm-dd

1

yyyy/mm/dd

2

dd/mm/yyyy

3

mm/dd yy

Memory address

Memory definition

unsigned int 16 value

Corresponding option

Remarks

0700

led brightness

0

low

1

medium

2

high

Memory address

Memory definition

unsigned int 16 value

Corresponding option

Remarks

0701

lcd brightness

0

low

1

medium

2

high

Memory address

Memory definition

unsigned int 16 value

Corresponding option

Remarks

0702

green light

0

always on

1

10 seconds

2

60 seconds

Memory address

Memory definition

unsigned int 16 value

Corresponding option

Remarks

0703

Language

0

English

1

Traditional Chinese

2

Simplified Chinese

Memory address

Memory definition

unsigned int 16 value

Corresponding option

Remarks

0706

Lock Device

0

Off

1

On

2

60 seconds

Last updated