Parameters Table
Parameter Categorizing Table
Serial number
Name
Function
Z
Easy Setup
Z group has the most commonly used functions in other categories arranged in order to facilitate users to adjust the machine.
A
Measure
A group is about flow volume measurement
B
Unit
B group is about unit
K
Calibration
K group is related to Field Calibration
C
Total
C group is about accumulated
D
Alarm & Info (Alarm & Information)
D group is about alarm and notification.
E
Commute
E group adjust OCT 4-20mA and RS485
F
Simulate
F group is about simulation mode for communication and alarm testing.
H
System
H group is for other host settings
Parameter Description
Z Quick Setup Parameter List
Z01
Fully Auto Setup
Automatically execute Z02+Z03+Z04.
Z02
Auto Pipe Spec
Automatically detect pipeline specifications, and automatically jump to A02 to display the results after completion. This function is the same as A01.
Z03
Auto Initialization
Enabling this function will allow the flowmeter to adjust the signal state based on the environmental conditions. Please execute this function once every time you reinstall. This function is the same as A21.
(After installation is complete or if the pipeline size or material is changed, please perform Auto Initialize (Z03) and Auto Zero Offset (Z04) again to improve the accuracy of the flow meter readings and ensure product stability.)
Z04
Auto Zero Offset
Please install the pipeline on a pipeline that is still and full inside, and activate this function to correct the zero flow error. This function is the same as A22.
(After installation is complete or if the pipeline size or material is changed, please perform Auto Initialize (Z03) and Auto Zero Offset (Z04) again to improve the accuracy of the flow meter readings and ensure product stability.)
Z05
Scale Factor
Multiply the measured flow data by a fixed ratio, ranging from 0.001 to 1000. For negative flow, please go to A17 to set. This setting is synchronized with K03.
A Measure Parameter List
Serial number
Name
Function
A01
Auto Pipe Spec
Automatically detect pipeline specifications, and automatically jump to A02 to display the results after completion. This function is the same as Z02.
A02
Pipe Type
Select the line model to correct the data. Or select "Custom" to customize the pipe size and material.
(After installation is complete or if the pipeline size or material is changed, please perform Auto Initialize (Z03) and Auto Zero Offset (Z04) again to improve the accuracy of the flow meter readings and ensure product stability.)
A03
Pipe Geo. Unit
Pipe gauge unit, synchronized with B06.
(After installation is complete or if the pipeline size or material is changed, please perform Auto Initialize (Z03) and Auto Zero Offset (Z04) again to improve the accuracy of the flow meter readings and ensure product stability.)
A04
Pipe OD
Can be set when A01 is "custom". Dimensions are in accordance with B06. After adjustment, A04 and A06 will be automatically recalculated.
(After installation is complete or if the pipeline size or material is changed, please perform Auto Initialize (Z03) and Auto Zero Offset (Z04) again to improve the accuracy of the flow meter readings and ensure product stability.)
A05
Pipe Perimeter
Can be set when A01 is "custom". Dimensions are in accordance with B06. After adjustment, A03 and A06 will be automatically recalculated.
(After installation is complete or if the pipeline size or material is changed, please perform Auto Initialize (Z03) and Auto Zero Offset (Z04) again to improve the accuracy of the flow meter readings and ensure product stability.)
A06
Pipe thickness
Can be set when A01 is "custom". Dimensions are in accordance with B06. A06 will automatically recalculate after adjustment.
(After installation is complete or if the pipeline size or material is changed, please perform Auto Initialize (Z03) and Auto Zero Offset (Z04) again to improve the accuracy of the flow meter readings and ensure product stability.)
A07
Pipe ID
Can be set when A01 is "custom". Dimensions are in accordance with A02.
(After installation is complete or if the pipeline size or material is changed, please perform Auto Initialize (Z03) and Auto Zero Offset (Z04) again to improve the accuracy of the flow meter readings and ensure product stability.)
A08
Pipe Material
Set the pipe material, modify the flow data or select "Custom" to customize the sound velocity of the pipe.
(After installation is complete or if the pipeline size or material is changed, please perform Auto Initialize (Z03) and Auto Zero Offset (Z04) again to improve the accuracy of the flow meter readings and ensure product stability.)
A09
Pipe Soundspeed
When A08 is customized, you can manually set the sound velocity of the pipe, and the unit is set in B04.
A10
Liq. Type
Select the fluid type to correct the data. Or select "Custom" to customize fluid parameters.
A11
Auto Liq. Sound Speed
A12
Liq. Sound Speed
When A10 is customized, the fluid sound velocity can be manually set, and the unit is set in B04.
A13
Liq. Dyna. Viscosity
A15
Damping
A16
Direction
A17
Neg Flow (Negative Flow)
A18
Zero Cutoff
A19
Fast Update
A20
Anti-Noise
A21
Auto Initialization
A22
Auto Zero Offset
A23
Zero Offset
A24
Startup Pipe Check
B Unit Parameter List
Serial number
Name
Function
B01
Vol. Unit (Volume Unit)
Unit of instantaneous flow speed, default liter.
Metric: L, m3
B02
Time Unit
Unit of flow time seconds, minutes, hours, days. Default minutes.
B03
Total Unit (Total Volume Unit)
Unit of cumulative and history flow volume, default litre.
Metric: L, m3
B04
VelocityUnit
Unit of flow speed, default m/s.
Metric: m/s
Imperial: ft/s
B05
Dec. Place (Decimal Place)
For setting digits displayed after the decimal point on LCD and LED by using the round down method. The maximum number of digits is 4 digits.
B06
Pipe Geo. Unit
K On site Calibration Parameter List
K02
Calibra. Mode
K03
Scale Factor
K04
Manual Offset
Subtract the fixed instantaneous flow rate from the input value, and the unit is the same as the system setting value. For example, inputting 1.0 means that when the original instantaneous flow is 3.0, the instantaneous flow will be output at 2.0.
C Total Parameter List
Serial number
Name
Function
C01
Total Method
Set cumulative calculation direction. There are 3 options available: forward flow, reverse flow, and net flow volume. Switching method will set the cumulative volume to zero. Default method is forward flow.
C02
Del.
Total(Delete Total)
D Alarm & Information Parameter List
Serial number
Name
Function
D01
Sensor Error Alarm.
Alarm-A0
D02
Pipe Sensor Alarm
Alarm-A1
D03
Bad UltraS. Signal
Alarm-C3
D04
Off Pipe Alarm.
Alarm-A4
Alarm when the flowmeter is not installed correctly on the pipeline.
D05
FlowLIM Ala
(Flow Volume Limit Alarm)
Alarm-B
D06
Up LIM (Upper Limit)
D07
Low LIM (Lower Limit)
D08
Hysteresis%
(Hysteresis Percentage)
Set the hysteresis percentage for the release of the flow upper and lower limit alarms
Percentages are defined as percentages of the upper and lower bounds.
The range is 0-33%, and the default value is 3%.
This parameter must be a positive value.
D09
Total Ala. (Total Alarm)
Alarm-B
D10
Total Trig. (Total Alarm Trigger Condition)
Set the notification condition of the cumulative target value (D08), greater than the target or less than the target.
D11
Total Target
D12
Iout Alarm
Alarm B
D13
Speed Alarm
Alarm B
D14
PulseOverlap
Alarm B
D15
IoutStatAla (Iout Status Alarm)
D16
Install Issue
E Commute Parameter List
Serial number
Name
Function
E01
NC/NO
E02
OCT Info
There are options below are options to define OCT output, default OFF:
OFF,
Alarm A,
Alarm A+B,
Alarm A+B+C,
flow volume alarm(adjusted by D04 D05 D06),
cumulation alarm(adjusted by D08 D09 D10),
E03
Pulse Width
If E02 selects pulse v2, set the pulse time width in this item, optional 0.5ms (millisecond), 1ms, 10ms, default 0.5 ms.
E04
Modbus ID
Set up Modbus ID location, default 1.
E05
Baud
E06
Iout Def. (Iout Definition)
E07
4mA Value
/0mA Value
E08
20mA Value
E09
Iout Error
Set up the outputted value when the flow volume is not between E07 and E08.
4 Options modes:
2.4 and 21.6 mA (When less than E07, it outputts 2.4mA. When greater than E08, it outputs 21.6mA)
2.4 mA
21.6 mA
0 or 4 & 20mA (When less than or equal to E07, it outputts 4mA or 0mA (According to E13). When greater than or equal to E08, it outputs 20mA)
E11
4mA Adj. uA (4mA Output Adjustment in microAmp)/
0mA Adj. uA (0mA Output Adjustment in microAmp)
Fine tune 0 or 4mA output value, the unit is uA.
After fine tuning and saving the setting, output current will be varied for immediate check.
E12
20mA Adj. uA (20mA Output Adjustment in microAmp)
Fine tune 20mA output value, the unit is uA.
After fine tuning and saving the setting, output current will be varied for immediate check.
E13
Iout Range
To define the output range of Analog signals, there are 2 options:
4-20mA
0-20mA
E14
PulseV2 Unit
Define how much flow volume to output a pulse, the unit is determined by B01 as follows:
The unit of L and m3 is Litre.
The unit of U.gal(US Gallon) and ft3 is U.gal.
E15
Byte Format
E16
Bit Order
E17
Endianness
F Simulate Parameter List
Serial number
Name
Function
F01
Sim. Volume (Simulation Volume)
F02
Sim. Mode (Simulation Mode)
Simulation function will be activated after selecting “ on ”, default off.
OCT (besides pulse), RS485 and Analog current output will be operated according to the changes of simulated data and cumulative flow.
Please be noted that cumulative flow and history data will be affected.
Simulate mode will be reminded on the screen.
H System Parameter List
Serial number
Name
Function
H01
LED Bri. (LED Brightness)
H02
LCD Bri. (LCD Brightness)
H03
Green Light
H04
Language
H06
Reset
H07
Lock Device
H08
Password
H09
Home Page
H10
Debug Page
H11
Engineering Mode
H12
System Info.
Last updated