FU-TX 310 Clamp-on Ultrasonic Flowmeter Manual v3.
  • This instruction manual version is v3.0
  • Firmware update date and version function description
  • 1. Product Introduction
    • 1.1 Specifications
    • 1.2 Important concepts
    • 1.3 Product features
    • 1.4 Product applications
    • 1.5 Measuring principle
    • 1.6 Product contents
    • 1.7 User interface
      • 1.7.1 Screen interfaces
      • 1.7.2 Buttons
      • 1.7.3 LED message
  • 2. Installation Method
    • 2.1 Power
    • 2.2 Ultrasonic probe
      • 2.2.1 Probe wiring
      • 2.2.2 Meter wiring
      • 2.2.3 Installation location
      • 2.2.4 Installation method
      • 2.2.5 ​Probe installation method
    • 2.3 Temperature sensor/Analog output
      • 2.3.1 Temperature sensor
      • 2.3.2 Analog output
      • 2.3.3 RS485
    • 2.4 Installation check
      • 2.4.1 RSSI (Signal Strength)
      • 2.4.2 Q value
      • 2.4.3 Flight time
  • 3. Output Interface
  • 4. Setting up the Interface
    • 4.1 Intial menu settings
    • 4.2 Units
    • 4.3 Meter (Measurement Settings)
    • 4.4 Communication
    • 4.5 Other
    • 4.6 Save
  • 5. Error Messages and Solutions
  • 6. Other Conditions
  • 7. MODBUS Communication Protocol
  • 8. Cautions
  • 9. Sound Speeds Data
  • LORRIC Integration and Application Center
Powered by GitBook
On this page

Was this helpful?

Export as PDF
  1. 4. Setting up the Interface

4.2 Units

Measurement Unit

Metric or Imperial units

Flow Numerator

  1. m³ (Cubic meter)

  2. L (Liter) = 10-3 * m³

  3. gal (US gallons) = 3.785412 * 10-3 m³

  4. igl (Imperial gallons) = 4.54609 * 10-3 m³

  5. mgl (million US gallons) = 3785412 * 10-3 m³

  6. cf (Cubic feet) = 28.3164847 * 10-3 m³

  7. bal (US liquid barrel) = 35.23907 * 10-3m³

  8. ob (Oil barrel) = 158.987295 * 10-3m³

Flow Denominator

  1. sec (seconds)

  2. min (minutes)

  3. hr (hours)

  4. day (days)

Totalizer Units

Same as flow denominator (volume) units

Totalizer Decimal

Up to 7 digits can be set; decimal point position can be changed.

Enable NET Total

Turns net cumulative flow on or off (note that cumulative flow automatically zeroes at > 4,000,000,000,000 m3 ).

Enable POS Total

Turns positive cumulative flow on or off (cumulative flow automatically zeroes at > 4,000,000,000,000 m3 ).

Enable NEG Total

Turns negative accumulated flow on or off (accumulated flow automatically zeroes at > 4,000,000,000,000 m3 )

Reset Totalizer

Can be zero net, positive, or negative cumulative flow, or all zero at the same time.

Temperature Unit

Set temperature units:

1. °C (degrees Celsius)

2. °F (degrees Fahrenheit)