Besides other agreements, our standard package contains:
T-connector * 1
Union standard package contains
Union nuts * 2
Union adapter * 2
Union O-ring * 2
T-connector is generally shipped with a paddle set.
UPVC T-connector
If you can not see the pipe model you are currently using in the list or have other compatibility requirements, please ask our sales representative.
Parts
Material
T-connector
UPVC, PPH or PVDF (for order made)
Nuts
UPVC, PPH or PVDF (for order made)
Union adapter
UPVC, PPH or PVDF (for order made)
Paddle set screws
Stainless steel 304
O-ring
EPDM、VITON、FEPM (for order made)
A
B
C
D
E
F
G
H
½"
164
100
27.6
36
62.3
46.2
115.7
82.2
¾"
168
100
32.6
41.9
60
50.5
115.7
85.7
1"
168
100
40.6
50
60
60
115.7
85.7
1¼"
210
114
50.2
59.6
65
75.6
127
89.2
1½"
218
120
56
65.7
70
83
134
92.5
2"
269.5
133.3
72
81
81
99.7
148.8
99
A
B
C
D
E
F
2½"
160
70
76
92
106.5
152.5
I
J
63
63
Pipe diameter
Model
Metric ratio (pulses per litre)
US Gallon (pulses per US gal)
UK Gallon (pulses per UK gal)
3/4"
FP-P020
67.23
254.48
305.62
1"
FP-P025
53.33
201.89
242.46
1-1/4"
FP-P032
24.44
92.51
111.11
1-1/2"
FP-P040
17.02
64.43
77.38
2"
FP-P050
9.86
37.31
44.81
2-1/2"
FP-P065
5.42
20.52
24.64
LED monitor mainly provides high contrast numbers display for high visibility even in a dark environment.
LED monitor also provides 5 displayed digits within a decimal point which mainly displays real-time and accumulated flow volume data. For more digits of data, such as historical data and long-term cumulative data, please see the LCD.
LCD monitor allows display for 16 English characters in 3 rows . The first row is current content with units. The second row is data. The third row is a definition of each button.
The LCD screen has a 3-color backlit display. Definition of each color light as below:
Geen: Real-time data, device is working normally.
Red:
Blinking red light: Alarm A- Major error. Please see the “Alarm and Description of System Conditions” page for more details.
Continuous red light: Alarm B- Current status of the device meets the parameters set-up by the user so must pay attention to it. Alarm C- The calendar battery needs to be replaced.
Orange: Non real-time data display. Historical data query and set-up page display.
There are 4 buttons on the device, the definition of each button will be displayed at the upper row on the LCD screen. Generally, the leftmost button stands for “Exit” or “Back to last page”. The middle 2 buttons are for users to review page by page, modify data, or switch option. The rightmost button stands for “Set” or “Confirm”. Previously mentioned definitions are only for general use. For some other use scenarios, button definitions are modifiable for usability or error proof.
Besides other agreements, our standard package contains:
FP-AS510 Device * 1
2m 8pin cable * 1
Quick starting manuel * 1
Screws to connect the device and paddle set (Locking screws with your convenient side is suggested. It is unnecessary locking screws both sides)
Paddle set and T-connector can be purchased separately
Power supply
OCT output
Analog output (4-20mA, 0-20mA)
Digital communication Modbus RTU RS485
Besides other agreements, our standard package contains:
Paddle set (incl. paddle base, paddle wheel, shaft) * 1
Paddle set M4 screws * 4
Paddle set O-ring * 1
Paddle set could be purchased separately, or shipped with a T-connector.
Size of each part will affect the accuracy of flow volume monitoring. We suggest using OEM parts for correct results.
The video about the introduction of device, paddle set, T-connector and power cable.
Watch the video or scan the the QR code below.
* 316L Stainless Steel:ETA 2021.
** IP66:The IP Code, International Protection Marking, IEC standard 60529, sometimes interpreted as Ingress Protection Marking, classifies and rates the degree of protection provided by mechanical casings and electrical enclosures against intrusion, dust, accidental contact, and water. The first digit indicates the level of protection that the enclosure provides against access to hazardous parts (e.g., electrical conductors, moving parts) and the ingress of solid foreign objects. The second digit indicates the level of protection that the enclosure provides against harmful ingress of water.
First 6 stands for dust tight: No ingress of dust; complete protection against contact (dust tight). A vacuum must be applied. Test duration of up to 8 hours based on air flow.
Second 6 stands for powerful water jets: Water projected in powerful jets (12.5 mm) against the enclosure from any direction shall have no harmful effects.
*** The device is calibrated with normal temperature water. Fluids with different viscosities may have different results, and may also change the minimum and maximum flow velocity.
**** The flow velocity range may be slightly different due to factors such as piping diameter and fluid coefficient.
Parts
Material
Screws for top side housing
Stainless steel 304
Screen cover
PMMA
Whole housing without screen cover
PC+GF
Buttons
PET
2 meters long 8 pin cable with insulation cover
Union nuts of 2 meters long 8 pin cable
Oring of 2 meters long 8 pin cable
Sealing ring for top housing
M12 8 pin
Power supply
Working specification
12V ~ 36V 90mA (4-20mA and RS485 current are not included.)
Reverse voltage protection
Yes
Overcurrent protection
200mA
OCT output
Power supply spec
5V~30V 200mA
Reverse voltage protection
Yes
NPN connection
Yes
PNP connection
Yes
Maximum output frequency
700Hz
Overcurrent protection
200mA
Analog output (4-20mA, 0-20mA)
Wiring
4 wiring
Power supply
Device is self-powered, no external power supply required.
Maximum output range
0~21.6mA
Response time
<1s, the same as screen data.
Loop Resistance
1100 ohm @ 36V
600 ohm @ 24V
250 ohm @ 12V
Digital communication Modbus RTU RS485
Baud
9600, 19200, 38400, 57600
Wiring
2 wiring
Nodes on the bus
32
Parts
Material
Paddle Wheel
Al2O3
Shaft sleeve
Al2O3
Paddle
PVDF or PPH
Paddle base
UPVC, PPH or PVDF (for order made)
Paddle set O-ring
EPDM, VITON, FEPM (for order made)
Paddle set M4 screws
Stainless steel 304
Mechanism Specs |
Installation method | in-line (Pipe segment) |
Fluid in pipes temperature | UPVC:0~50 °C (32~122°F), For higher temperature, please use PPH or PVDF or 316L Stainless Steel* |
Device working environment temperature | -10~60°C (14~140°F) |
T-connector adapter | UPVC Gluing adapter(ASTM, JIS, DIN) UPVC internal and external thread adapter (BSPT and NPT), PPH / PVDF insertion welding fitting, UPVC / PPH / PVDF Spigot |
T-connector diameter | DN15-65 (½" to 2-1/2") |
Paddle material | PVDF or PPH with embedded magnet + ceramic bearing and shaft |
T-connector material | UPVC / PPH / PVDF (Made to order)/ 316L Stainless Steel* |
Power supply | DC 12V to 36V 100mA |
Response time | < 0.5 or 1 second |
Waterproof level | IP66 ** |
Measurement Specs |
Applicable fluid maximum dynamic viscosity | 300cSt*** |
Applicable fluid | Clear, oil or chemicals with less impurities (<1%) |
Linearity | ± 0.5 % FS (>0.3m/s) |
Reproducibility | ± 0.4 % |
OR tolerance | ± 2.5 % OR |
Measuring principle | Paddle Wheel |
Flow velocity range | ± 0.3~10m/s Can extend to ± 0.15m ~ 10m/s **** |
Transient data | Instantaneous flow volume and flow velocity |
Cumulative data | Positive and negative net flow volume accumulation, past 14 days and long time accumulative net flow volume. |
User Interface |
Language | English, Traditional Chinese, Simplified Chinese (Others customizable) |
Unit | Metric: Litre, cubic meters, meters Imperial: foot, Cubic foot, Uk gallon, US gallon Time: second, minute, hour, day |
Display | Double screen display : Large 5-Digit LED, 16x3 3-Color Backlight LCD display |
Display digits | LED 5 Digits (4 digits when negative value)/ LCD 10 Digits (Not including sign and decimal point) |
Operation buttons | 4 Key touch buttons |
Wired communication | Self-powered Analog output 4-20mA (Device after HW1.3) Modbus RTU RS485 Two-line OCT switch signal (ship with 2 meter cable) |
Calendar function battery | CR2032 |