A05 Pipe Perimeter
Definition
Set the pipe circumference. Default values vary depending on the selected pipe unit.
DN15
69.08 mm
2.72 inch
47.1 mm 1.854 inch
94.2 mm
3.709 inch
DN20
81.64 mm
3.214 inch
56.52 mm
2.225 inch
109.9 mm 4.327 inch
DN25
100.4 mm 3.956 inch
75.36 mm
2.967 inch
135.02 mm
5.316 inch
DN32
119.32 mm
4.698 inch
94.2 mm 3.709 inch
166.42 mm
6.552 inch
DN40
150.72 mm
5.934 inch
113.04 mm
4.45 inch
204.1 mm
8.035 inch
DN50
188.4 mm
7.417 inch
144.44 mm
5.687 inch
244.92 mm
9.643 inch
DN65
238.64 mm
9.395 inch
182.12 mm
7.17 inch
288.88 mm 11.373 inch
DN75
279.46 mm
11.002 inch
219.8 mm 8.654 inch
376.8 mm 14.835 inch
DN100
358.14 mm
14.1 inch
329.16 mm
12.959 inch
359.08 mm
14.137 inch
DN125
439.82 mm
17.316 inch
408.96 mm 16.101 inch
443.91 mm
17.477 inch
DN150
515.22 mm
20.284 inch
488.77 mm
19.243 inch
528.67 mm
20.814 inch
DN200
678.58 mm 26.716 inch
648.36 mm
25.526 inch
706.86 mm
27.829 inch
DN250
838.81 mm
33.024 inch
807.95 mm
31.809 inch
879.65 mm 34.632 inch
DN300
999.03 mm
39.332 inch
967.55 mm
38.092 inch
1017.4 mm
40.055 inch
DN350
1162.39 mm
45.763 inch
1115.27 mm
43.908 inch
1162.39 mm
45.763 inch
DN400
1319.47 mm
51.948 inch
1256.64 mm
49.474 inch
1319.47 mm
51.948 inch
Notes
Pipe size units are determined by B06 (Pipe Size Unit).
Each time the pipe size is changed, please re-execute Z03 Auto Initialize and Z04 Auto Zero Offset to improve measurement accuracy and ensure stable product performance.
On certain firmware versions, a pipe material confirmation page will appear after setting A05 Pipe Wall Thickness. Please select the matching pipe material or choose Custom. If a predefined pipe material is selected, A08 (Pipe Material) will be synchronized automatically.
For DN100–DN400, this parameter is calculated as outer diameter × π from the Default/Minimum/Maximum values in A04, which are themselves sourced from A02 (Preset Pipe Spec).
Operation Procedure

A05 Options, RS485 Values, Read/Write Commands, and Formats
Custom
Refer to the table above
-
Minimum
-
Maximum
-
Refer to the Read/Write Memory List for the Modbus command format. This parameter uses the float32 data format.