A04 Pipe Outer Diameter

Definition

Set the pipe outer diameter. Default values vary depending on the selected pipe unit.

Pipe OD
DN15
DN20
DN25
DN32

Default

mm

22

26

32

38

inch

0.866

1.024

1.260

1.496

Minimum

mm

15

18

24

30

inch

0.591

0.709

0.945

1.181

Maximum

mm

30

35

43

53

inch

1.181

1.378

1.693

2.087

Pipe OD
DN40
DN50
DN65
DN75

Default

mm

48

60

76

89

inch

1.890

2.362

2.992

3.504

Minimum

mm

36

46

58

70

inch

1.417

1.811

2.283

2.756

Maximum

mm

65

78

92

120

inch

2.559

3.071

3.622

4.724

  1. Millimeters (mm) are used as the base unit, while inches are provided as converted values (conversion reference: 1 inch = 25.4 mm).

  2. If a value exceeds four decimal places, it will be truncated to four decimal places without rounding.

Notes

  1. Pipe size units are determined by B06 (Pipe Size Unit).

  2. Each time the pipe size is changed, please re-execute Z03 Auto Initialize and Z04 Auto Zero Offset to improve measurement accuracy and ensure stable product performance.

  3. On certain firmware versions, a pipe material confirmation page will appear after setting A04 Pipe Wall Thickness. Please select the matching pipe material or choose Custom. If a predefined pipe material is selected, A08 (Pipe Material) will be synchronized automatically.

Operation Procedure

Button Functions (Click to Expand)

When the main screen is displayed in green backlight, the four buttons function as follows:

  • Blue Button (leftmost): Return, exit, or save settings.

  • Gray Direction Buttons:

    • Left Gray: Previous Page, decrease value, or select item

    • Right Gray: Next Page, increase value, or select item

  • Orange Button (rightmost): Rightmost button: Enter settings, edit, or confirm selection

Button functions may change depending on the operation context to improve usability or prevent accidental presses.

A04 Options, RS485 Values, Read/Write Commands, and Formats

Input Range of This Parameter
Corresponding Values
RS-485 Value

Custom

Refer to the table above

-

Minimum

-

Maximum

-

Refer to the Read/Write Memory List for the Modbus command format. This parameter uses the float 32 data format

Last updated