# E09 Iout Error

### Definition

Sets the output value when the flow reading is outside the range defined by E07 (4 mA value) and E08 (20 mA value). Default: 4 mA & 20 mA.

### Notes

N/A

### Operation Procedure

<details>

<summary><strong>Button Functions</strong> <em>(Click to Expand)</em></summary>

When the main screen is displayed in **green backlight**, the four buttons function as follows:

* <img src="https://4028902321-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FSBz5Tlpy8GCIkK4ygkgZ%2Fuploads%2FRnX1fMK1ja5FUx043ZYc%2Fimage?alt=media&#x26;token=f31dd577-ba27-4369-af8b-25ce9afcd1f9" alt="" data-size="line"> **Blue Button (leftmost):** Return, exit, or save settings.
* Gray Direction Buttons:
  * <img src="https://4028902321-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FSBz5Tlpy8GCIkK4ygkgZ%2Fuploads%2FR48KXgI2flteQ78PYH8a%2Fimage?alt=media&#x26;token=b5b4ab82-6f88-44c6-8b85-181c7bde6fe9" alt="" data-size="line"> **Left Gray:** Previous Page, decrease value, or select item
  * <img src="https://4028902321-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FSBz5Tlpy8GCIkK4ygkgZ%2Fuploads%2FVWLxHCjTZgj8Y3CXUn6X%2Fimage?alt=media&#x26;token=35556f59-f963-4b03-8db1-34f2953ddb58" alt="" data-size="line"> **Right Gray:** Next Page, increase value, or select item
* <img src="https://4028902321-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FSBz5Tlpy8GCIkK4ygkgZ%2Fuploads%2F0lsHAW4cWIphk6mKtEoK%2Fbutton-orange.png?alt=media&#x26;token=9168c231-821c-4895-9194-0cf61b2fd06a" alt="" data-size="line"> **Orange Button (rightmost):** Rightmost button: Enter settings, edit, or confirm selection

{% hint style="danger" %}
**Do not hold buttons for extended periods to avoid damage.**
{% endhint %}

{% hint style="info" %}
Button functions may change depending on the operation context to improve usability or prevent accidental presses.
{% endhint %}

</details>

```
E09 Iout Error Setting Steps
• From the main screen (green backlight), 
  press Orange Button (Setup) to enter settings (orange backlight).
• Use Gray Arrow Buttons to select E. Commute , press Orange Button (Enter).
• Use Gray Arrow Buttons to select E09 Iout Error , press Orange Button (Enter).
• Use Gray Arrow Buttons to choose the options. 
• Press Orange Button (Set) to confirm.
• Press Blue Button (ESC) to return to the main screen (green backlight).
```

<figure><img src="https://4028902321-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FSBz5Tlpy8GCIkK4ygkgZ%2Fuploads%2FI0HJKG5uC60VfdXcpXCb%2Ffu-es-E09-en.png?alt=media&#x26;token=7012651e-a155-4128-b602-d5ed1e490fff" alt="" width="563"><figcaption></figcaption></figure>

### E09 Options, RS485 Values, Read/Write Commands, and Formats

<table><thead><tr><th width="211.880859375">Option</th><th>Description</th><th width="158.876953125">RS-485 Value</th></tr></thead><tbody><tr><td>2.4 mA ＆ 21.6 mA</td><td>Output 2.4 mA when the value is below E07, and 21.6 mA when the value exceeds E08.</td><td>0</td></tr><tr><td>2.4 mA</td><td>Forces the output to the lower-limit signal when below the normal range.</td><td>1</td></tr><tr><td>21.6 mA</td><td>Forces the output to the upper-limit signal when above the normal range.</td><td>2</td></tr><tr><td>4mA ＆ 20mA (Default)</td><td>Clamps the output current to the boundaries of the normal operating range.</td><td>3</td></tr></tbody></table>

> Refer to the [Read/Write Memory List](https://docs.lorric.com/qr/fu-es-echosense-instruction-manual/communication/modbus-rtu-protocol/read-write-memory-ram) for the Modbus command format. This parameter uses the Int16 data format.