D16 Dosing Alarm
Definition
Set the flow meter’s alarm mode when the totalizer reaches the preset target (C04). Default: Do Not Disturb.
Notes
DND Mode
When Do Not Disturb (DND) mode is enabled:
The flow meter detects abnormal conditions but the red backlight will not turn on. Example: Alarm-A “4 Off Pipe” will not trigger the backlight in DND mode.
Abnormal conditions are still displayed on the Status/Alarm page.
If connected via RS485, the monitoring system still receives the alarm signal.
OCT alarm outputs continue to operate if configured.
Operation Procedure
D16 Dosing Alarm Setting Steps
• From the main screen (green backlight),
press Orange Button (Setup) to enter settings (orange backlight).
• Use Gray Arrow Buttons to select D. Alarm & Info, press Orange Button (Enter).
• Use Gray Arrow Buttons to select D16 Dosing Alarm, press Orange Button (Enter).
• Use Gray Arrow Buttons to choose the options.
• Press Orange Button (Set) to confirm.
• Press Blue Button (ESC) to return to the main screen (green backlight).
D16 Options, RS485 Values, Read/Write Commands, and Formats
Option
Description
RS-485 Value
Off
-
0
On
-
1
Do Not Disturb (Default)
-
2
Refer to the Read/Write Memory List for the Modbus command format. This parameter uses the Int16 data format.