D Alarm & Info
No.
Name
Description
D01
Sensor Error Alarm.
Alarm-A0
Alarm when the ultrasonic module is abnormal. Do not disturb mode is preset.
D02
Pipe Sensor Alarm
Alarm-A1
Alarm when the module detecting pipe diameter is abnormal. Do not disturb mode is preset.
D03
Bad UltraS. Signal
Alarm-C3
Alarm when the ultrasonic signal is poor. Do not disturb mode is preset.
D04
Off Pipe Alarm.
Alarm-A4
Alarm when the flowmeter is not installed correctly on the pipeline.
Preset Do Not Disturb Mode: The red light will not flash, but the flow will return to zero when the alarm occurs, and the alarm a04 will become 1. on - When the alarm occurs, the red light will flash, the flow will return to zero, and the alarm a04 will become 1.
D05
FlowLIM Ala
(Flow Volume Limit Alarm)
Alarm-B
Set the alarm when the instantaneous flow rate exceeds the range, which can be turned off. The default is off.
D06
Up LIM (Upper Limit)
Defines the upper normal range of flow for D04.
D07
Low LIM (Lower Limit)
Defines the flow normal range lower limit for D04.
D08
Hysteresis%
(Hysteresis Percentage)
Set the hysteresis percentage for the release of the flow upper and lower limit alarms
Percentages are defined as percentages of the upper and lower bounds.
The range is 0-33%, and the default value is 3%.
This parameter must be a positive value.
D09
Total Ala. (Total Alarm)
Alarm-B
The alarm can be set to be turned off when the accumulated flow range is exceeded. The default is off.
D10
Total Trig. (Total Alarm Trigger Condition)
Set the notification condition of the cumulative target value (D08), greater than the target or less than the target.
The preset is larger than the target.
D11
Total Target
Set the cumulative target value.
D12
Iout Alarm
Alarm B
Set whether to alarm when it exceeds the range of 4-20mA, and it can be closed. The default is off.
D13
Speed Alarm
Alarm B
Set whether to alarm when the absolute value of the flow velocity exceeds the range of 6m/s, which can be turned off. On by default.
D14
PulseOverlap
Alarm B
Pulse output (Pulse output) signal overlap alarm. The setting of parameter E03 is too large, resulting in overlapping of Pulse Output output signals. Can be turned off, default is on.
D15
IoutStatAla (Iout Status Alarm)
Set the Iout state warning mode, selectable on, off and do not disturb mode (Do not disturb), default do not disturb mode. The Do Not Disturb mode means that when an abnormality occurs, the color and LED displayed on the screen will not change, but it can still display numbers in the communication part and display abnormalities on the status page.
D16
Install Issue
Alarm - C2 The signal quality is not ideal due to poor installation of the flowmeter. It is recommended to lock the flowmeter evenly to achieve the best signal quality. Default non-disturbance mode: no light, Alarm C2 displays 1.