> For the complete documentation index, see [llms.txt](https://docs.lorric.com/qr/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://docs.lorric.com/qr/fu-es-echosense-instruction-manual/parameters/c-total/c02-del.total.md).

# C02 Del.Total

### Definition

Set the flow meter’s totalizer to zero manually. Default: No.&#x20;

### Notes

N/A

### Operation Procedure

<details>

<summary><strong>Button Functions</strong> <em>(Click to Expand)</em></summary>

When the main screen is displayed in **green backlight**, the four buttons function as follows:

* <img src="/files/bdd75120acea6361d128fd3deec06f1a8277e667" alt="" data-size="line"> **Blue Button (leftmost):** Return, exit, or save settings.
* Gray Direction Buttons:
  * <img src="/files/2e37e572251371c6020ab6d9e11c1fcdd5ef0369" alt="" data-size="line"> **Left Gray:** Previous Page, decrease value, or select item
  * <img src="/files/50a67ff5744401e217d5b9e838da3f7909be732f" alt="" data-size="line"> **Right Gray:** Next Page, increase value, or select item
* <img src="/files/uJJ6BEZ4sukIlwQaHrUB" alt="" data-size="line"> **Orange Button (rightmost):** Rightmost button: Enter settings, edit, or confirm selection

{% hint style="danger" %}
**Do not hold buttons for extended periods to avoid damage.**
{% endhint %}

{% hint style="info" %}
Button functions may change depending on the operation context to improve usability or prevent accidental presses.
{% endhint %}

</details>

```
C02 Del. Total Setting Steps
• From the main screen (green backlight), 
  press Orange Button (Setup) to enter settings (orange backlight).
• Use Gray Arrow Buttons to select C. Total , press Orange Button (Enter).
• Use Gray Arrow Buttons to select C02 Del. Total, press Orange Button (Enter).
• Use Gray Arrow Buttons to choose the options. 
• Press Orange Button (Set) to confirm.
• Press Blue Button (ESC) to return to the main screen (green backlight).
```

<figure><img src="/files/2oKLUtmaqUYh4kyno9r0" alt="" width="563"><figcaption></figcaption></figure>

### C02 Options – RS485 Values, Read/Write Commands, and Format

| Option       | Description     | RS-485 Value |
| ------------ | --------------- | ------------ |
| No (Default) | No Reset        | 0            |
| Yes          | Reset Totalizer | 1            |

> Refer to the [Read/Write Memory List](/qr/fu-es-echosense-instruction-manual/communication/modbus-rtu-protocol/read-write-memory-ram/read-write-memory-read-list.md) for the Modbus command format. \
> The data type for this parameter is **Int16**.

#### RS485 Remote Totalizer Reset (C02 Del. Total)

| Item             | Description                  |
| ---------------- | ---------------------------- |
| Parameter Name   | C02 Del. Total               |
| Description      | Resets the Totalizer to zero |
| Register Address | 02 01                        |
| Register Length  | 1                            |
| Data Type        | int16                        |
| Read Command     | Function Code 03             |
| Write Command    | Function Code 06             |

#### 1.Read Current Status (Function Code 03)

The master can use Function Code 03 to read the current status of C02:

* Return value = `0`: Not triggered (default)
* Return value = `1`: Reset action triggered

#### 2.Execute Totalizer Reset (Function Code 06)

The master can use Function Code 06 to write a specified value to the C02 register to trigger the reset:

* Write Value: `1` (Int16)
* After writing, the device immediately resets the Totalizer to zero.


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation dynamically by asking a question.

Perform an HTTP GET request on the current page URL with the `ask` query parameter, and the optional `goal` query parameter:

```
GET https://docs.lorric.com/qr/fu-es-echosense-instruction-manual/parameters/c-total/c02-del.total.md?ask=<question>&goal=<endgoal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is optional and describes the broader end goal you are ultimately trying to accomplish on behalf of the user. GitBook uses it to tailor the answer towards what is most useful for that goal.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.