# C Total

<table data-header-hidden><thead><tr><th width="119.33333333333331">Serial number</th><th width="183">Name</th><th>Function</th></tr></thead><tbody><tr><td>No.</td><td>Name</td><td>Description</td></tr><tr><td>C01</td><td>Total Method</td><td>Set cumulative calculation direction. There are 3 options available: forward flow, reverse flow, and net flow volume. Switching method will set the cumulative volume to zero. Default method is forward flow.  </td></tr><tr><td>C02</td><td><p>Del.</p><p>Total(Delete Total)</p></td><td>Set cumulative flow volume to 0. First select "Yes" then save.</td></tr><tr><td>C03</td><td>Dosing Mode</td><td>Manually adjusts the dosing mode to either <strong>Count Up</strong> (incremental) or <strong>Count Down</strong> (decremental). Default setting: Off.</td></tr><tr><td>C04</td><td>Dosing Target</td><td>Sets the target value for dosing operations. Default value: 1000.</td></tr><tr><td>C05</td><td>Dosing Reset Time</td><td>Resets the dosing timer. Minimum value: 1 second. Default value: 300 seconds.</td></tr></tbody></table>