# A02 Preset Pipe Spec

### Definition

This function is used to select the piping specifications used by the flow meter, with CNS PVCU as the default.

<table data-header-hidden><thead><tr><th>Model  (Pipe Diameter)</th><th valign="top">Pipe Spec Options (Metal)</th><th>Pipe Spec Options (Plastic)</th><th valign="top">Pipe Spec Options (Others)</th></tr></thead><tbody><tr><td>FU-ES015 (DN15)</td><td valign="top"><p><strong>Metal</strong></p><ul><li>ASTM 1/2" Sch40 SS304</li><li>JIS G3459 NO.15</li></ul></td><td><p><strong>Plastic</strong></p><ul><li>CNS W15 PVCU</li><li>CNS E15 PVCU</li><li>JIS K6742 NO.15</li><li>ASTM 3/4" Sch40 PVCU</li><li>ASTM 1/2" Sch80 PVCU</li><li>ISO 15 PP</li><li>ISO 15 PVDF</li></ul></td><td valign="top"><p><strong>Others</strong></p><ul><li>Custom</li></ul></td></tr><tr><td>FU-ES020 (DN20)</td><td valign="top"><p><strong>Metal</strong></p><ul><li>ASTM 3/4" Sch40 SS304</li><li>JIS G3459 NO.20</li></ul></td><td><p><strong>Plastic</strong></p><ul><li>CNS W20 PVCU</li><li>CNS E20 PVCU</li><li>JIS K6742 NO.20</li><li>ASTM 1" Sch40 PVCU</li><li>ASTM 3/4" Sch80 PVCU</li><li>ISO 20 PP</li><li>ISO 20 PVDF</li></ul></td><td valign="top"><p><strong>Others</strong></p><ul><li>Custom</li></ul></td></tr><tr><td>FU-ES025 (DN25)</td><td valign="top"><p><strong>Metal</strong></p><ul><li>ASTM 1" Sch40 SS304</li><li>JIS G3459 NO.25</li></ul></td><td><p><strong>Plastic</strong></p><ul><li>CNS W25 PVCU</li><li>CNS E25 PVCU</li><li>JIS K6742 NO.25</li><li>ASTM Sch40 PVCU</li><li>ASTM 1" Sch80 PVCU</li><li>ISO 25 PP</li><li>ISO 25 PVDF</li></ul></td><td valign="top"><p><strong>Others</strong></p><ul><li>Custom</li></ul></td></tr><tr><td>FU-ES032 (DN32)</td><td valign="top"><p><strong>Metal</strong></p><ul><li>ASTM Sch40 SS304</li><li>JIS G3459N 0.32</li></ul></td><td><p><strong>Plastic</strong></p><ul><li>CNS W32 PVCU</li><li>CNS E32 PVCU</li><li>JIS K6742N 0.32</li><li>ASTM Sch40 PVCU</li><li>ASTM Sch80 PVCU</li><li>ISO 32 PP</li><li>ISO 32 PVDF</li></ul></td><td valign="top"><p><strong>Others</strong></p><ul><li>Custom</li></ul></td></tr><tr><td>FU-ES040 (DN40)</td><td valign="top"><p><strong>Metal</strong></p><ul><li>ASTM Sch40 SS304</li><li>JIS G3459N 0.40</li></ul></td><td><p><strong>Plastic</strong></p><ul><li>CNS W40 PVCU</li><li>CNS E40 PVCU</li><li>JIS K6742N 0.40</li><li>ASTM Sch40 PVCU</li><li>ASTM Sch80 PVCU</li><li>ISO 40 PP</li><li>ISO 40 PVDF</li></ul></td><td valign="top"><p><strong>Others</strong></p><ul><li>Custom</li></ul></td></tr><tr><td>FU-ES050 (DN50)</td><td valign="top"><p><strong>Metal</strong></p><ul><li>ASTM Sch40 SS304</li><li>JIS G3459 NO.50</li></ul></td><td><p><strong>Plastic</strong></p><ul><li>CNS W50 PVCU</li><li>CNS E50 PVCU</li><li>JIS K6742 NO.50</li><li>ASTM Sch40 PVCU</li><li>ASTM Sch80 PVCU</li><li>ISO 50 PP</li><li>ISO 50 PVDF</li></ul></td><td valign="top"><p><strong>Others</strong></p><ul><li>Custom</li></ul></td></tr><tr><td>FU-ES065 (DN65)</td><td valign="top"><p><strong>Metal</strong></p><ul><li>ASTM Sch40 SS304</li><li>JIS G3459 NO.65</li></ul></td><td><p><strong>Plastic</strong></p><ul><li>CNS W65 PVCU</li><li>CNS E65 PVCU</li><li>JIS K6742 NO.65</li><li>ASTM Sch40 PVCU</li><li>ASTM Sch80 PVCU</li><li>ISO 65 PP</li><li>ISO 65 PVDF</li></ul></td><td valign="top"><p><strong>Others</strong></p><ul><li>Custom</li></ul></td></tr><tr><td>FU-ES075 (DN75)</td><td valign="top"><p><strong>Metal</strong></p><ul><li>ASTM Sch40 SS304</li><li>JIS G3459 NO.75</li></ul></td><td><p><strong>Plastic</strong></p><ul><li>CNS W75 PVCU</li><li>CNS E75 PVCU</li><li>JIS K6742N NO.75</li><li>ASTM Sch40 PVCU</li><li>ASTM Sch80 PVCU</li><li>ISO 75 PP</li><li>ISO 75 PVDF</li></ul></td><td valign="top"><p><strong>Others</strong></p><ul><li>Custom</li></ul></td></tr></tbody></table>

### Notes

1. <mark style="color:red;">Each time the pipeline size is changed, perform</mark> <mark style="color:red;"></mark><mark style="color:red;">**Z03 Auto Initialize**</mark> <mark style="color:red;"></mark><mark style="color:red;">and</mark> <mark style="color:red;"></mark><mark style="color:red;">**Z04 Auto Zero Offset**</mark> <mark style="color:red;"></mark><mark style="color:red;">to ensure accurate flow readings and maintain stable product quality。</mark>
2. Tube specifications vary depending on the model and firmware version. Confirm the machine’s model and version to select the correct tube specification table. To check the model and version, follow the steps below:：

<table><thead><tr><th valign="top">H12 System Info</th><th valign="top">Startup Screen</th><th valign="top">Device Label</th></tr></thead><tbody><tr><td valign="top"><p>Access parameter H12 – System Info to verify the device model and main unit version.</p><ul><li><strong>P1205</strong>: Device firmware version (identical to the version shown on the startup screen)</li><li><strong>D1205</strong> and <strong>S1101</strong>: Hardware version</li><li><strong>025</strong>: Device model (DN25 pipe size)</li></ul></td><td valign="top"><p>The startup screen is displayed for approximately three seconds after the flowmeter is powered on.</p><ul><li><strong>LORRIC</strong>: Trademark</li><li><strong>FU-ES 025</strong>: Device model (DN25 pipe size)</li><li><strong>P1205</strong> Device firmware version</li></ul></td><td valign="top"><p>A label is affixed to the flowmeter housing.</p><ul><li><strong>FU-ES 025</strong>: Device model (DN25 pipe size)</li><li><strong>22UD00433</strong> Device serial number</li></ul><p>• <strong>Hardware 1.0/2.0</strong> refers to the product's hardware version.</p><p>Note: The label may become unreadable over time. It's recommended to record the serial number upon receipt.</p></td></tr><tr><td valign="top"><img src="https://4028902321-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FSBz5Tlpy8GCIkK4ygkgZ%2Fuploads%2F2zt0FPC5GH5giAx0bNMP%2Ffu-es-H12-system-square.png?alt=media&#x26;token=ddf11317-1060-47b0-899a-b2230346c737" alt="" data-size="original"></td><td valign="top"><img src="https://4028902321-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FSBz5Tlpy8GCIkK4ygkgZ%2Fuploads%2FLCklJd1mOXCJCcXe26le%2Ffu-es-H12-splashscreen-square.png?alt=media&#x26;token=83841a05-51ee-481e-88ae-c51ba341d052" alt="" data-size="original"></td><td valign="top"><img src="https://4028902321-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FSBz5Tlpy8GCIkK4ygkgZ%2Fuploads%2FjLTubJCDiDJL86UCjk8N%2FFU-ES-product-label-marked.png?alt=media&#x26;token=94903bbd-afa3-478c-95bd-4bbde337511e" alt="" data-size="original"></td></tr></tbody></table>

### Operation Procedure

<details>

<summary><strong>Button Functions</strong> <em>(Click to Expand)</em></summary>

When the main screen is displayed in **green backlight**, the four buttons function as follows:

* <img src="https://4028902321-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FSBz5Tlpy8GCIkK4ygkgZ%2Fuploads%2FRnX1fMK1ja5FUx043ZYc%2Fimage?alt=media&#x26;token=f31dd577-ba27-4369-af8b-25ce9afcd1f9" alt="" data-size="line"> **Blue Button (leftmost):** Return, exit, or save settings.
* Gray Direction Buttons:
  * <img src="https://4028902321-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FSBz5Tlpy8GCIkK4ygkgZ%2Fuploads%2FR48KXgI2flteQ78PYH8a%2Fimage?alt=media&#x26;token=b5b4ab82-6f88-44c6-8b85-181c7bde6fe9" alt="" data-size="line"> **Left Gray:** Previous Page, decrease value, or select item
  * <img src="https://4028902321-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FSBz5Tlpy8GCIkK4ygkgZ%2Fuploads%2FVWLxHCjTZgj8Y3CXUn6X%2Fimage?alt=media&#x26;token=35556f59-f963-4b03-8db1-34f2953ddb58" alt="" data-size="line"> **Right Gray:** Next Page, increase value, or select item
* <img src="https://4028902321-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FSBz5Tlpy8GCIkK4ygkgZ%2Fuploads%2F0lsHAW4cWIphk6mKtEoK%2Fbutton-orange.png?alt=media&#x26;token=9168c231-821c-4895-9194-0cf61b2fd06a" alt="" data-size="line"> **Orange Button (rightmost):** Rightmost button: Enter settings, edit, or confirm selection

{% hint style="danger" %}
**Do not hold buttons for extended periods to avoid damage.**
{% endhint %}

{% hint style="info" %}
Button functions may change depending on the operation context to improve usability or prevent accidental presses.
{% endhint %}

</details>

<pre><code>A02 Present Pipe Spec Setting Steps
• From the main screen (green backlight), press Orange Button (Setup) to enter settings (orange backlight).
<strong>• Use Gray Arrow Buttons to select A. Measurement, press Orange Button (Enter).
</strong><strong>• Use Gray Arrow Buttons to select A02 Preset Pipe Spec, press Orange Button (Enter).
</strong>• Use Gray Arrow Buttons to choose the pipe specification.
• Press Orange Button (Set) to confirm.
<strong>• Press Blue Button (ESC) to return to the main screen (green backlight).
</strong></code></pre>

<figure><img src="https://4028902321-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FSBz5Tlpy8GCIkK4ygkgZ%2Fuploads%2FiWcgl67LUBpceLJd8fHa%2Ffu-es-A02-en.png?alt=media&#x26;token=f269df74-5715-4adb-bf89-8c5f838c7dbc" alt="" width="563"><figcaption></figcaption></figure>

### A02 Options and RS485 Values, Read/Write Commands, and Formats

Refer to the tube specification table corresponding to the model.

#### A02 Pipe Specification — Model FU-ES015, Version P1203 / P1205 Parameter Table

<table data-full-width="false"><thead><tr><th>015</th><th>RS-485 int</th></tr></thead><tbody><tr><td>custom</td><td>0 </td></tr><tr><td>CNS W15 PVCU</td><td>1</td></tr><tr><td>CNS E15 PVCU</td><td>2</td></tr><tr><td>JIS K6742NO.15</td><td>3</td></tr><tr><td>ASTM¾"Sch40PVCU</td><td>4</td></tr><tr><td>ASTM½"Sch40SS304</td><td>5</td></tr><tr><td>ASTM½"Sch80PVCU</td><td>6</td></tr><tr><td>JIS G3459NO.15</td><td>7</td></tr><tr><td>ISO 15 PP</td><td>8</td></tr><tr><td>ISO 15 PVDF</td><td>9</td></tr></tbody></table>

#### A02 Pipe Specification — Model FU-ES020, Version P1203 / P1205 Parameter Table

<table data-full-width="false"><thead><tr><th>020</th><th>RS-485 int</th></tr></thead><tbody><tr><td>custom</td><td>0 (Default)</td></tr><tr><td>CNS W20 PVCU</td><td>1</td></tr><tr><td>CNS E20 PVCU</td><td>2</td></tr><tr><td>JIS K6742NO.20</td><td>3</td></tr><tr><td>ASTM1"Sch40PVCU</td><td>4</td></tr><tr><td>ASTM¾"Sch40SS304</td><td>5</td></tr><tr><td>ASTM¾"Sch80PVCU</td><td>6</td></tr><tr><td>JIS G3459NO.20</td><td>7</td></tr><tr><td>ISO 20 PP</td><td>8</td></tr><tr><td>ISO 20 PVDF</td><td>9</td></tr></tbody></table>

#### A02 Pipe Specification — Model FU-ES025, Version P1203 / P1205 Parameter Table

<table data-full-width="false"><thead><tr><th>020</th><th>RS-485 int</th></tr></thead><tbody><tr><td>custom</td><td>0 (Default)</td></tr><tr><td>CNS W25 PVCU</td><td>1</td></tr><tr><td>CNS E25 PVCU</td><td>2</td></tr><tr><td>JIS K6742NO.25</td><td>3</td></tr><tr><td>ASTM1"Sch40PVCU</td><td>4</td></tr><tr><td>ASTM1"Sch40SS304</td><td>5</td></tr><tr><td>ASTM1"Sch80PVCU</td><td>6</td></tr><tr><td>JIS G3459NO.25</td><td>7</td></tr><tr><td>ISO 25 PP</td><td>8</td></tr><tr><td>ISO 25 PVDF</td><td>9</td></tr></tbody></table>

#### A02 Pipe Specification — Model FU-ES032, Version P1203 / P1205 Parameter Table

<table data-full-width="false"><thead><tr><th>032</th><th>RS-485 int</th></tr></thead><tbody><tr><td>custom</td><td>0 (Default)</td></tr><tr><td>CNS W32 PVCU</td><td>1</td></tr><tr><td>CNS E32 PVCU</td><td>2</td></tr><tr><td>JIS K6742NO.32</td><td>3</td></tr><tr><td>ASTMSch40PVCU</td><td>4</td></tr><tr><td>ASTMSch40SS304</td><td>5</td></tr><tr><td>ASTMSch80PVCU</td><td>6</td></tr><tr><td>JIS G3459NO.32</td><td>7</td></tr><tr><td>ISO 32 PP</td><td>8</td></tr><tr><td>ISO 32 PVDF</td><td>9</td></tr></tbody></table>

#### A02 Pipe Specification — Model FU-ES040, Version P1203 / P1205 Parameter Table

<table data-full-width="false"><thead><tr><th>040</th><th>RS-485 int</th></tr></thead><tbody><tr><td>custom</td><td>0 (Default)</td></tr><tr><td>CNS W40 PVCU</td><td>1</td></tr><tr><td>CNS E40 PVCU</td><td>2</td></tr><tr><td>JIS K6742NO.40</td><td>3</td></tr><tr><td>ASTMSch40PVCU</td><td>4</td></tr><tr><td>ASTMSch40SS304</td><td>5</td></tr><tr><td>ASTMSch80PVCU</td><td>6</td></tr><tr><td>JIS G3459NO.40</td><td>7</td></tr><tr><td>ISO 40 PP</td><td>8</td></tr><tr><td>ISO 40 PVDF</td><td>9</td></tr></tbody></table>

#### A02 Pipe Specification — Model FU-ES050, Version P1203 / P1205 Parameter Table

<table data-full-width="false"><thead><tr><th>050</th><th>RS-485 int</th></tr></thead><tbody><tr><td>custom</td><td>0 (Default)</td></tr><tr><td>CNS W50 PVCU</td><td>1</td></tr><tr><td>CNS E50 PVCU</td><td>2</td></tr><tr><td>JIS K6742NO.50</td><td>3</td></tr><tr><td>ASTMSch40PVCU</td><td>4</td></tr><tr><td>ASTMSch40SS304</td><td>5</td></tr><tr><td>ASTMSch80PVCU</td><td>6</td></tr><tr><td>JIS G3459NO.50</td><td>7</td></tr><tr><td>ISO 50 PP</td><td>8</td></tr><tr><td>ISO 50 PVDF</td><td>9</td></tr></tbody></table>

#### A02 Pipe Specification — Model FU-ES065, Version P1203 / P1205 Parameter Table&#x20;

<table data-full-width="false"><thead><tr><th>065</th><th>RS-485 int</th></tr></thead><tbody><tr><td>custom</td><td>0 (Default)</td></tr><tr><td>CNS W65 PVCU</td><td>1</td></tr><tr><td>CNS E65 PVCU</td><td>2</td></tr><tr><td>JIS K6742NO.65</td><td>3</td></tr><tr><td>ASTMSch40PVCU</td><td>4</td></tr><tr><td>ASTMSch40SS304</td><td>5</td></tr><tr><td>ASTMSch80PVCU</td><td>6</td></tr><tr><td>JIS G3459NO.65</td><td>7</td></tr><tr><td>ISO 65 PP</td><td>8</td></tr><tr><td>ISO 65 PVDF</td><td>9</td></tr></tbody></table>

#### A02 Pipe Specification — Model FU-ES075, Version P1203 / P1205 Parameter Table

<table data-full-width="false"><thead><tr><th>075</th><th>RS-485 int</th></tr></thead><tbody><tr><td>custom</td><td>0 (Default)</td></tr><tr><td>CNS  W75 PVCU</td><td>1</td></tr><tr><td>CNS  E75 PVCU</td><td>2</td></tr><tr><td>JIS K6742NO.75</td><td>3</td></tr><tr><td>ASTMSch40PVCU</td><td>4</td></tr><tr><td>ASTMSch40SS304</td><td>5</td></tr><tr><td>ASTMSch80PVCU</td><td>6</td></tr><tr><td>JIS G3459NO.75</td><td>7</td></tr><tr><td>ISO 75 PP</td><td>8</td></tr><tr><td>ISO 75 PVDF</td><td>9</td></tr></tbody></table>

Refer to the [Read/Write Memory List](https://docs.lorric.com/qr/fu-es-echosense-instruction-manual/communication/modbus-rtu-protocol/read-write-memory-ram/read-write-memory-read-list) for the Modbus command format. This parameter uses the Int16 data format.