H01 LED Bri.
Definition
Sets the LCD brightness of the flow meter. Four options available: High, Medium, Low, and Off. Default: Medium.
Notes
N/A
Operation Procedure
H01 LED Bri. Setting Steps
• From the main screen (green backlight),
press Orange Button (Setup) to enter settings (orange backlight).
• Use Gray Arrow Buttons to select H. System , press Orange Button (Enter).
• Use Gray Arrow Buttons to select H01 LED Bri. , press Orange Button (Enter).
• Use Gray Arrow Buttons to choose the options.
• Press Orange Button (Set) to confirm.
• Press Blue Button (ESC) to return to the main screen (green backlight).
H01 Options, RS485 Values, Read/Write Commands, and Formats
Option
Description
RS-485 Value
Low
-
0
Medium (Default)
-
1
High
-
2
Off
-
3
Refer to the Read/Write Memory List for the Modbus command format. This parameter uses the Unsigned Int16 (UINT16) data format.
Last updated