> For the complete documentation index, see [llms.txt](https://docs.lorric.com/qr/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://docs.lorric.com/qr/fp-as510-paddle-wheel-flowmeter-manual-en-v2/parameters-table/e-commute.md).

# E Commute

### E Commute **parameter list** <a href="#e-parameter-list" id="e-parameter-list"></a>

<table data-header-hidden><thead><tr><th width="109.33333333333331">Serial number</th><th width="193">Name</th><th>Function</th></tr></thead><tbody><tr><td><strong>Serial number</strong></td><td>Name</td><td>Function</td></tr><tr><td>E01</td><td>NC/NO</td><td>Under normal conditions(when the oct condition does not meet). OCT should be closed(connected) or open (disconnected). The default is open.</td></tr><tr><td>E02</td><td>OCT Info</td><td><p>There are options below are options to define OCT output, default OFF:</p><p>OFF,</p><p>Alarm A,</p><p>Alarm A+B,</p><p>Alarm A+B+C,</p><p>flow volume alarm(adjusted by D04 D05 D06),</p><p>cumulation alarm(adjusted by D08 D09 D10),</p><p>paddle wheel pulse output( adjusted by E03, please refer to the <a href="/qr/fp-as510-paddle-wheel-flowmeter-manual-en-v2/communication/oct-output.md">OCT output</a> for instructions).</p><p>PulseV2( adjusted by E03 and E14, please refer to the <a href="/qr/fp-as510-paddle-wheel-flowmeter-manual-en-v2/communication/oct-output.md">OCT output</a> for instructions).</p></td></tr><tr><td>E03</td><td>Pulse Width</td><td>If paddlewheel pulse is selected in E02, you set the pulse width to 0.5 ms (millisecond), 1ms, or 10ms. The default is 0.5ms. Every 180° paddlewheel rotation will output a pulse. Please refer to the <a href="/qr/fp-as510-paddle-wheel-flowmeter-manual-en-v2/communication/oct-output.md">Pulse- flow volume conversion chart</a> for flow volume calculation.</td></tr><tr><td>E04</td><td>Modbus ID</td><td>Set up Modbus ID location, default 1.</td></tr><tr><td>E05</td><td>Baud</td><td>You can set-up Modbus communication baud rate at turnning off, 9600, 19200, 38400, or 57600. Default off.</td></tr><tr><td>E06</td><td><p>Iout Def.</p><p>(Iout Definition)</p></td><td>For setting output data of Analog signal, 4 options are available, off, flowrate, velocity, total. The unit is according to parameter group B. Default off.</td></tr><tr><td>E07</td><td>4mA Value /0mA Value</td><td>Set up corresponding value to 0 or 4mA, default 0. Both positive and negative values work. The value should be smaller than 20mA.</td></tr><tr><td>E08</td><td>20mA Value</td><td>Set up corresponding value to 20mA, default 100. Both positive and negative values work. The value should be larger than 4mA.</td></tr><tr><td>E09</td><td>Iout Error</td><td><p>Set up the outputted value when the flow volume is not between E07 and E08.</p><p>4 Options modes:</p><ol><li>2.4 and 21.6 mA (When less than E07, it outputts 2.4mA. When greater than E08, it outputs 21.6mA)</li><li>2.4 mA</li><li>21.6 mA</li><li><p>0 or 4 &#x26; 20mA (When less than or equal to E07,  it outputts 4mA or 0mA (According to E13). When greater than or equal to E08, it outputs </p><p>20mA)</p></li></ol><p>Default 0 or 4 &#x26; 20mA.</p></td></tr><tr><td>E11</td><td><p>4mA Adj. uA</p><p>(4mA Output Adjustment in microAmp)/</p><p>0mA Adj. uA<br>(0mA Output Adjustment in microAmp)</p></td><td><p>Fine tune 0 or 4mA outputted value, the unit is uA.</p><p>After fine tuning and saving the setting, output current will be varied for immediate check.</p><p>Positive value increases output current, negative value decreases output current.</p></td></tr><tr><td>E12</td><td><p>20mA Adj. uA</p><p>(20mA Output Adjustment in microAmp)</p></td><td><p>Fine tune 20mA outputted value, the unit is uA.</p><p>After fine tuning and saving the setting, ooutput current will be varied for immediate check.</p><p>Positive value increases output current, negative value decreasess output current.</p></td></tr><tr><td>E13</td><td>Iout Range</td><td><p>To define the output range of Analog signals, there are 2 options:</p><ol><li>4-20mA</li><li>0-20mA</li></ol><p>Default is 4-20mA. Modifying this item will affect the options of E09. After modify this item, please confirm E09 meets the requirements.</p></td></tr><tr><td>E14</td><td>PulseV2 Unit</td><td><p>Define how much flow volume to output a pulse, the unit is determined by B01 as follows：</p><ol><li>The unit of L and m3 is  Litre.</li><li>The unit of U.gal(US Gallon) and ft3 is U.gal.</li><li>The unit of I.gal(Imperial Gallon) is I.gal.</li></ol></td></tr><tr><td>E15</td><td>Byte format</td><td>Please refer to <a href="/qr/fp-as510-paddle-wheel-flowmeter-manual-en-v2/communication/rs485.md">RS485 and Modbus RTU Setting</a> for more information. (available since FW 2.3.0)</td></tr><tr><td>E16</td><td>Bit order</td><td>Please refer to <a href="/qr/fp-as510-paddle-wheel-flowmeter-manual-en-v2/communication/rs485.md">RS485 and Modbus RTU Setting</a> for more information. (available since FW 2.3.0)</td></tr><tr><td>E17</td><td>Endianness</td><td>Please refer to <a href="/qr/fp-as510-paddle-wheel-flowmeter-manual-en-v2/communication/rs485.md">RS485 and Modbus RTU Setting</a> for more information. (available since FW 2.3.0)</td></tr></tbody></table>

**The video about E parameter setup.**

Watch the video or scan the the QR code below. \
(\*Please refer to the parameter list of this version of the manual for the new and modified parameters)

{% embed url="<https://youtu.be/yJa05lrbgf0>" %}
The video about E parameter setup
{% endembed %}

![The video about E parameter setup](https://498068148-files.gitbook.io/~/files/v0/b/gitbook-legacy-files/o/assets%2F-M7fZsO11LItbPHrVN6W%2F-MKd5NvM3QEV2qX0PxZS%2F-MKdHQNunWtJWK6ILHhG%2F%E5%8F%83%E6%95%B8%20E%20%E5%88%86%E9%A1%9E%E8%A8%AD%E5%AE%9A%E5%BD%B1%E7%89%87_en.jpg?alt=media\&token=61e0e51c-0cf7-4148-a95a-2196312214e0)


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://docs.lorric.com/qr/fp-as510-paddle-wheel-flowmeter-manual-en-v2/parameters-table/e-commute.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.
