C Total & History

C Total & History Parameter List

Serial number

Name

Function

C01

Total Method

Set cumulative calculation direction. There are are 3 options available: forward flow, reverse flow, and net flow volume. Switching method will set cumulative volume to zero. Default method is forward flow.

C02

Del. Total

(Delete Total)

Set cumulative flow volume to 0. First select "Yes" then save.

C03

History Func (History Function)

To turn on/off history recording function. If turned off, the historical records of the past 14 days will not be displayed on the monitoring screen. Default off.

C04

Del. History

(Delete History)

Set historical flow volume to 0. First select "Yes" then save.

The video about C parameter setup.

Watch the video or scan the the QR code below. (*Please refer to the parameter list of this version of the manual for the new and modified parameters)