B02 Time Unit
Definition
Sets the time unit for instantaneous flow. Default: minute.
Notes
N/A
Operation Procedure
B02 Time Unit Setting Steps
• From the main screen (green backlight),
press Orange Button (Setup) to enter settings (orange backlight).
• Use Gray Arrow Buttons to select B. Unit , press Orange Button (Enter).
• Use Gray Arrow Buttons to select B02 Time Unit, press Orange Button (Enter).
• Use Gray Arrow Buttons to choose the options.
• Press Orange Button (Set) to confirm.
• Press Blue Button (ESC) to return to the main screen (green backlight).
B02 Options, RS485 Values, Read/Write Commands, and Formats
Option
Description
RS-485 Value
Second
-
0
Minute (Default)
-
1
Hour
-
2
Day
-
3
Refer to the Read/Write Memory List for the Modbus command format. This parameter uses the Unsigned Int16 (UINT16) data format.
Last updated