A Measuremeent Setup

A Measure Parameter list

Serial number

Name

Function

A01

Pipe Type

Set the T-connector spec to use the correct calibration data. The default is 1 inch.

A02

Scales Factor

Fine tune flow volume in proportion, default value is 1.0.

A03

Anti-Noise

Eliminate measurement noise. Default on.

A04

Damping

Decrease the fluctuation of data, the lowest is 0, default value is 3 seconds.

A05

Direction

Option to exchange flow direction, default normal.

A06

Neg Flow

(Negative Flow)

Option to show reverse flow volume, default on.

A07

Ext. Mode

(Extension Mode)

Option to measure flow speed under 0.3m/s, default on.

A08

Fast Update

Increase the screen update interval to less than 0.5 seconds, default off.

The video about the monitoring screen, setup screen and A parameter setup.

Watch the video or scan the QR code below. (*Please refer to the parameter list of this version of the manual for the new and modified parameters)

The video about the monitoring screen, setup screen and A parameter setup