# Exterior, Spec, Model

## **Exterior**

![](https://498068148-files.gitbook.io/~/files/v0/b/gitbook-legacy-files/o/assets%2F-M7fZsO11LItbPHrVN6W%2F-M7f_TuZUIGjiNsFn4zu%2F-M7faVeJsRLO5xkfTfyb%2Fmanual%20detail%20images-en.jpg?alt=media\&token=748e214c-249f-40ef-a4d5-ab4dbf4633b4)

## **Exploded views**

![](https://498068148-files.gitbook.io/~/files/v0/b/gitbook-legacy-files/o/assets%2F-M7fZsO11LItbPHrVN6W%2F-M7f_TuZUIGjiNsFn4zu%2F-M7falHN7Ejr3iPgI94L%2FFP-AS510-exploded%20views.jpg?alt=media\&token=d3a84690-d53d-4a9f-8998-0529748a114f)

**The video about the introduction of device, paddle set, T-connector and power cable.**

Watch the video or scan the the QR code below.

{% embed url="<https://www.youtube.com/watch?v=Id55JWI-P90>" %}
LORRIC FP AS510 Paddle Wheel Flowmeter Product Introduction Video
{% endembed %}

![LORRIC FP-AS510 Paddle Wheel Flowmeter Product Introduction Video](https://498068148-files.gitbook.io/~/files/v0/b/gitbook-legacy-files/o/assets%2F-M7fZsO11LItbPHrVN6W%2F-M7f_TuZUIGjiNsFn4zu%2F-M7fbCT-g_TAuvWaYY-6%2FLORRIC-FP-%20AS510-Video-en.png?alt=media\&token=d8eb32d9-19c3-4db6-8767-2886e3d43022)

## **Products specs**<br>

| Mechanism Specs                        |                                                                                                                                                                           |
| -------------------------------------- | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
| Installation method                    | in-line (Pipe segment)                                                                                                                                                    |
| Fluid in pipes temperature             | UPVC：0\~50 °C (32\~122°F), For higher temperature, please use PPH or PVDF or 316L Stainless Steel\*                                                                       |
| Device working environment temperature | -10\~60°C (14\~140°F)                                                                                                                                                     |
| T-connector adapter                    | <p>UPVC Gluing adapter(ASTM, JIS, DIN) UPVC internal and external thread adapter (BSPT and NPT),</p><p>PPH / PVDF insertion welding fitting, UPVC / PPH / PVDF Spigot</p> |
| T-connector diameter                   | DN15-65 (½" to 2-1/2")                                                                                                                                                    |
| Paddle material                        | PVDF or PPH with embedded magnet + ceramic bearing and shaft                                                                                                              |
| T-connector material                   | UPVC / PPH / PVDF (Made to order)/ 316L Stainless Steel\*                                                                                                                 |
| Power supply                           | DC 12V to 36V 100mA                                                                                                                                                       |
| Response time                          | < 0.5 or 1 second                                                                                                                                                         |
| Waterproof level                       | IP66 \*\*                                                                                                                                                                 |

| Measurement Specs                          |                                                                                                              |
| ------------------------------------------ | ------------------------------------------------------------------------------------------------------------ |
| Applicable fluid maximum dynamic viscosity | 300cSt\*\*\*                                                                                                 |
| Applicable fluid                           | Clear, oil or chemicals with less impurities (<1%)                                                           |
| Linearity                                  | ± 0.5 % FS (>0.3m/s)                                                                                         |
| Reproducibility                            | ± 0.4 %                                                                                                      |
| OR tolerance                               | ± 2.5 % OR                                                                                                   |
| Measuring principle                        | Paddle Wheel                                                                                                 |
| Flow velocity range                        | <p>± 0.3\~10m/s </p><p>Can extend to ± 0.15m \~ 10m/s \*\*\*\*</p>                                           |
| Transient data                             | Instantaneous flow volume and flow velocity                                                                  |
| Cumulative data                            | Positive and negative net flow volume accumulation, past 14 days and long time accumulative net flow volume. |

| User Interface            |                                                                                                                                                       |
| ------------------------- | ----------------------------------------------------------------------------------------------------------------------------------------------------- |
| Language                  | English, Traditional Chinese, Simplified Chinese (Others customizable)                                                                                |
| Unit                      | <p>Metric: Litre, cubic meters, meters</p><p>Imperial: foot, Cubic foot, Uk gallon, US gallon</p><p>Time: second, minute, hour, day</p>               |
| Display                   | Double screen display : Large 5-Digit LED, 16x3 3-Color Backlight LCD display                                                                         |
| Display digits            | LED 5 Digits (4 digits when negative value)/ LCD 10 Digits (Not including sign and decimal point)                                                     |
| Operation buttons         | 4 Key touch buttons                                                                                                                                   |
| Wired communication       | <p>Self-powered Analog output 4-20mA (Device after HW1.3)</p><p>Modbus RTU RS485 Two-line</p><p>OCT switch signal</p><p>(ship with 2 meter cable)</p> |
| Calendar function battery | CR2032                                                                                                                                                |

\* 316L Stainless Steel：ETA 2021.

\*\* IP66：The IP Code, International Protection Marking, IEC standard 60529, sometimes interpreted as Ingress Protection Marking, classifies and rates the degree of protection provided by mechanical casings and electrical enclosures against intrusion, dust, accidental contact, and water. The first digit indicates the level of protection that the enclosure provides against access to hazardous parts (e.g., electrical conductors, moving parts) and the ingress of solid foreign objects. The second digit indicates the level of protection that the enclosure provides against harmful ingress of water.

First 6 stands for dust tight: No ingress of dust; complete protection against contact (dust tight). A vacuum must be applied. Test duration of up to 8 hours based on air flow.

Second 6 stands for powerful water jets: Water projected in powerful jets (12.5 mm) against the enclosure from any direction shall have no harmful effects.

\*\*\* The device is calibrated with normal temperature water. Fluids with different viscosities may have different results, and may also change the minimum and maximum flow velocity.

\*\*\*\* The flow velocity range may be slightly different due to factors such as piping diameter and fluid coefficient.