E03 Pulse Width
Definition
Sets the pulse width of the flow meter when E02 OCT Definition is set to “Pulse output” or “Pulse v2”. Default: 1 ms.
Notes
To enable the pulse function, set E02 OCT Info to “Pulse v2”, configure the pulse width in E03 Pulse Width, set the forward flow unit in B01, and define the pulse output reference unit in E14 Pulse v2 Unit.
Operation Procedure
E03 Pulse Width Setting Steps
• From the main screen (green backlight),
press Orange Button (Setup) to enter settings (orange backlight).
• Use Gray Arrow Buttons to select E. Commute , press Orange Button (Enter).
• Use Gray Arrow Buttons to select E03 Pulse Width, press Orange Button (Enter).
• Use Gray Arrow Buttons to choose the options.
• Press Orange Button (Set) to confirm.
• Press Blue Button (ESC) to return to the main screen (green backlight).
E03 Options, RS485 Values, Read/Write Commands, and Formats
Option
Description
RS-485 Value
1 ms (Default)
-
1
10 ms
-
2
50 ms
-
3
100 ms
-
4
Last updated