E02 OCT Info
Definition
Sets the definition for the flow meter’s OCT operation. Default: Off.
Notes
If E02 is set to “Pulse v2”, configure the pulse width in E03 Pulse Time and set the pulse reference unit in E14 Pulse v2 Unit.
Flow alarms are configured via D04, D05, D06; Totalizer alarms via D08, D09, D10; Pulse v2 settings via E03, E14.
Operation Procedure
E02 OCT Info. Setting Steps
• From the main screen (green backlight),
press Orange Button (Setup) to enter settings (orange backlight).
• Use Gray Arrow Buttons to select E. Commute , press Orange Button (Enter).
• Use Gray Arrow Buttons to select E02 OCT Info., press Orange Button (Enter).
• Use Gray Arrow Buttons to choose the options.
• Press Orange Button (Set) to confirm.
• Press Blue Button (ESC) to return to the main screen (green backlight).
E02 Options, RS485 Values, Read/Write Commands, and Formats
Options
RS-485 Value
Alarm B
1
Pulse V2
6
Off (Default)
7