> For the complete documentation index, see [llms.txt](https://docs.lorric.com/qr/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://docs.lorric.com/qr/fp-as310-english-v5/parameters/e-commute/e-commute-fp-as310a.md).

# E Commute - FP-AS310A

<table data-header-hidden><thead><tr><th width="160.20001220703125"></th><th width="209.79998779296875"></th><th width="399.5999755859375"></th></tr></thead><tbody><tr><td><strong>No.</strong></td><td><strong>Name</strong></td><td><strong>Description</strong></td></tr><tr><td>E01</td><td>NC/NO</td><td><p>Sets whether the OCT output is open or closed when the condition is not met. The default setting is open.</p><p><mark style="color:orange;">(Only Applicable to Model FP-AS310A)</mark></p></td></tr><tr><td>E02</td><td>OCT Info</td><td>Sets the definition for the flow meter’s OCT operation. Default: Off. <br><mark style="color:orange;">(Only Applicable to Model FP-AS310A)</mark></td></tr><tr><td>E03</td><td>Pulse Width</td><td><p>Sets the pulse width of the flow meter when E02 OCT Definition is set to “Pulse v2”. Default: 0.5 ms.</p><p><mark style="color:orange;">(Only Applicable to Model FP-AS310A)</mark></p></td></tr><tr><td>E06</td><td>Iout Def.(Iout Definition)</td><td>Sets the data to be output via the analog signal. The unit follows the setting in Parameter B (Unit Configuration). Default: Off.<br><mark style="color:orange;">(Only Applicable to Model FP-AS310A)</mark></td></tr><tr><td>E07</td><td>4mA  Value</td><td><p>Set up corresponding value to 4mA, default 0. Both positive and negative values work. The value should be smaller than 20mA.</p><p><mark style="color:orange;">(Only Applicable to Model FP-AS310A)</mark></p></td></tr><tr><td>E08</td><td>20mA Value</td><td><p>Set up corresponding value to 20mA, default 100. Both positive and negative values work. The value should be larger than 4mA. </p><p><mark style="color:orange;">(Only Applicable to Model FP-AS310A)</mark></p></td></tr><tr><td>E11</td><td>4mA Adj. uA(4mA Output Adjustment in microAmp)</td><td><p>Fine-tunes the flow meter’s 4 mA output value. Unit: µA (microamperes). Default: 0.</p><p><mark style="color:orange;">(Only Applicable to Model FP-AS310A)</mark></p></td></tr><tr><td>E12</td><td>20mA Adj. uA(20mA Output Adjustment in microAmp)</td><td>Fine-tunes the flow meter’s 20 mA output value. Unit: µA (microamperes). Default: 0.<br><mark style="color:orange;">(Only Applicable to Model FP-AS310A)</mark></td></tr><tr><td>E14</td><td>PulseV2 Unit</td><td><p>Defines the flow rate corresponding to one pulse output from the flow meter.</p><p><mark style="color:orange;">(Only Applicable to Model FP-AS310A)</mark></p></td></tr></tbody></table>


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation dynamically by asking a question.

Perform an HTTP GET request on the current page URL with the `ask` query parameter:

```
GET https://docs.lorric.com/qr/fp-as310-english-v5/parameters/e-commute/e-commute-fp-as310a.md?ask=<question>
```

The question should be specific, self-contained, and written in natural language.
The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.
