E Commute

No.

Name

Description

E01

NC/NO

Sets whether the OCT output is open or closed when the condition is not met. The default setting is open.

(Only Applicable to Model FP-AS310A)

E02

OCT Info

Sets the definition for the flow meter’s OCT operation. Default: Off. (Only Applicable to Model FP-AS310A)

E03

Pulse Width

Sets the pulse width of the flow meter when E02 OCT Definition is set to “Pulse v2”. Default: 0.5 ms.

(Only Applicable to Model FP-AS310A)

E04

Modbus ID

Set up Modbus ID location, default 1.

(Only applicable to Model FP-AS310R)

E05

Baud

Sets the Modbus communication baud rate for the flow meter. The Master and Slave must use the same baud rate for communication. Default: Off. (Only applicable to Model FP-AS310R)

E06

Iout Def.(Iout Definition)

Sets the data to be output via the analog signal. The unit follows the setting in Parameter B (Unit Configuration). Default: Off. (Only Applicable to Model FP-AS310A)

E07

4mA Value

Set up corresponding value to 4mA, default 0. Both positive and negative values work. The value should be smaller than 20mA.

(Only Applicable to Model FP-AS310A)

E08

20mA Value

Set up corresponding value to 20mA, default 100. Both positive and negative values work. The value should be larger than 4mA.

(Only Applicable to Model FP-AS310A)

E11

4mA Adj. uA(4mA Output Adjustment in microAmp)

Fine-tunes the flow meter’s 4 mA output value. Unit: µA (microamperes). Default: 0.

(Only Applicable to Model FP-AS310A)

E12

20mA Adj. uA(20mA Output Adjustment in microAmp)

Fine-tunes the flow meter’s 20 mA output value. Unit: µA (microamperes). Default: 0. (Only Applicable to Model FP-AS310A)

E14

PulseV2 Unit

Defines the flow rate corresponding to one pulse output from the flow meter.

(Only Applicable to Model FP-AS310A)

E15

Byte format

Sets the data format for Modbus RTU communication. Default: N,8,1 (No parity, 8 data bits, 1 stop bit).

(Only applicable to Model FP-AS310R)

E16

Bit order

Sets the bit order for each byte during Modbus RTU transmission.

(Only applicable to Model FP-AS310R)

E17

Endianness

Sets the byte order for multi-byte data during RX (flow meter response) transmission.

(Only applicable to Model FP-AS310R)