A01 Pipe Type

Definition

Set the T-connector spec to use the correct calibration data. The default is 1 inch.

Notes

N/A

Operation Procedure

Button Functions (Click to Expand)

The main unit has four buttons. The bottom line (Line 3) of the LCD displays the current function of each button. Under normal operation, the button functions are as follows:

  • Blue Button: Leftmost button: Return, exit, or save settings.

  • Gray Direction Buttons:

    • Left Gray: Previous Page, decrease value, or select item

    • Right Gray: Next Page, increase value, or select item

  • Orange Button: Rightmost button: Enter settings, edit, or confirm selection

Button functions may change depending on the operation context to improve usability or prevent accidental presses

A01 Pipe Type Setting Steps
• From the main screen (green backlight), 
  press Orange Button (Setup) to enter settings (orange backlight).
• Select A. Measure by pressing Orange Button (Enter).
• Use Gray Arrow Buttons to select A01 Pipe Type, press Orange Button (Enter).
• Use Gray Arrow Buttons to choose the options. 
• Press Orange Button (Set) to confirm.
• Press Blue Button (ESC) to return to the main screen (green backlight).

A01 Options, RS485 Values, Read/Write Commands, and Formats

Options
Description
RS-485 Value

1 inch (Default)

0

3/4 inch

1

2 inch

2

Scale Mode

3

2-1/2 inch

4

1-1/4 inch

5

1-1/2 inch

6

1 inch v2

7

1/2 inch

8

1 PT M SS

9

3/4 PT F SS

10

1-1/2 PT F SS

11

2 PT F SS

12

Last updated